BodyTemperature-v1.2.1(2015EN): verschil tussen versies

Uit Zorginformatiebouwstenen
Ga naar: navigatie, zoeken
 
(2 tussenliggende versies door dezelfde gebruiker niet weergegeven)
Regel 1: Regel 1:
==General information==
+
<!-- Hieronder wordt een transclude page aangeroepen -->
Name: '''nl.nfu.BodyTemperature''' [[Bestand:NL.png|link=Lichaamstemperatuur-v1.2.1(2015NL)]]<BR>
+
{{Versions-2.16.840.1.113883.2.4.3.11.60.40.3.12.6(EN)|1|BodyTemperature-v1.2.1(2015EN)}}
Version: '''1.2.1''' <br>
+
<!-- Tot hier de transclude page -->
HCIM Status:Final<br>
+
==General information<!--hdGeneralInformation-->==
Release: '''2015''' <br>
+
Name<!--hdName-->: '''nl.nfu.BodyTemperature''' [[Bestand:NL.png|link=Lichaamstemperatuur-v1.2.1(2015NL)]]<BR>
Release status: Published<br>
+
Version<!--hdVersion-->: '''1.2.1''' <br>
Release date: 1-4-2015
+
HCIM Status<!--hdStatus-->:Final<br>
 +
Release<!--hdPublication-->: '''2015''' <br>
 +
Release status<!--hdPublicationStatus-->: Published<br>
 +
Release date<!--hdPublicationDate-->: 1-4-2015
 
-----
 
-----
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release_2015(EN)]] [[HCIM_Release_2015(EN) |Back to HCIM list ]]</div>
+
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2015(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2015(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div>
  
 
==Metadata==
 
==Metadata==
Regel 61: Regel 64:
 
==Revision History==
 
==Revision History==
 
<div class="mw-collapsible mw-collapsed">
 
<div class="mw-collapsible mw-collapsed">
''Only available in Dutch''
+
''Only available in Dutch<!--noTranslation-->''
  
 
<u>Publicatieversie 1.0</u> (15-02-2013)
 
<u>Publicatieversie 1.0</u> (15-02-2013)
Regel 127: Regel 130:
 
==Information Model==
 
==Information Model==
 
<BR>
 
<BR>
<imagemap> Bestand:BodyTemperature-v1.2.1Model(EN).png | center  
+
<imagemap> Bestand:BodyTemperature-v1.2.1Model(2015EN).png | center  
rect 576 250 728 297 [[#TemperatureTypeCodelist]]
+
rect 586 258 738 305 [[#TemperatureTypeCodelist]]
rect 195 87 303 157 [[#9541]]
+
rect 205 95 313 165 [[#9541]]
rect 353 238 503 308 [[#9544]]
+
rect 363 246 513 316 [[#9544]]
rect 580 86 724 156 [[#9542]]
+
rect 590 94 734 164 [[#9542]]
rect 195 238 303 308 [[#9543]]
+
rect 205 246 313 316 [[#9543]]
rect 371 87 485 157 [[#9540]]
+
rect 381 95 495 165 [[#9540]]
 
desc none
 
desc none
 
</imagemap>
 
</imagemap>
Regel 139: Regel 142:
 
{| border= "1"  width="1500px" style = "font-size: 9.5pt;  border: solid 1px silver; border-collapse:collapse;" cellpadding = "3px" cellspacing ="0px"  
 
{| border= "1"  width="1500px" style = "font-size: 9.5pt;  border: solid 1px silver; border-collapse:collapse;" cellpadding = "3px" cellspacing ="0px"  
 
|-style="background-color: #1F497D; color: white; font-weight: bold; font-variant: small-caps; "
 
|-style="background-color: #1F497D; color: white; font-weight: bold; font-variant: small-caps; "
|style="width:30px;"|Type||style="width:100px;"|Id||colspan="6 " style="width:140px;"|Concept||Card.||style="width: 600px;"|Definition||style="width:200px;"|DefinitionCode||style="width:200px;"|Reference
+
|style="width:30px;"|Type<!--imType-->||style="width:100px;"|Id<!--imId-->||colspan="6 " style="width:140px;"|Concept<!--imConcept-->||Card.<!--imCard-->||style="width: 600px;"|Definition<!--imDefinition-->||style="width:200px;"|DefinitionCode<!--imDefinitionCode-->||style="width:200px;"|Reference<!--imReference-->
 
|-style="vertical-align:top; background-color: #E3E3E3; "
 
|-style="vertical-align:top; background-color: #E3E3E3; "
 
|style = "text-align:center" |[[Bestand: block.png| 20px | link=]]
 
|style = "text-align:center" |[[Bestand: block.png| 20px | link=]]
Regel 158: Regel 161:
 
{|
 
{|
 
|-
 
|-
|<span Title="Codesystem: SNOMED CT"> 386725007 Body temperature (observable entity)
+
|<span title = "Codesystem: SNOMED CT>[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=386725007 386725007] Body temperature (observable entity)</span>
</span>
 
 
|}
 
|}
 
|
 
|
Regel 194: Regel 196:
 
|}
 
|}
 
|}
 
|}
Columns Concept and DefinitionCode: hover over the values for more information<BR>
+
Columns Concept and DefinitionCode: hover over the values for more information<!--imHover--><BR>
For explanation of the symbols, please see the legend page [[Bestand:list2.png|link=Legend]]
+
For explanation of the symbols, please see the legend page<!--imLegend--> [[Bestand:list2.png|link=Legend<!--wikiLegend-->]]
  
 
==Example Instances==
 
==Example Instances==
''Only available in Dutch''
+
''Only available in Dutch<!--noTranslation-->''
  
 
{|class="wikitable" width="542px" style= "font-size: 9.5pt;"
 
{|class="wikitable" width="542px" style= "font-size: 9.5pt;"
Regel 222: Regel 224:
 
{| class="wikitable" width="60%"  
 
{| class="wikitable" width="60%"  
 
|-style='vertical-align:top; background-color: #E8D7BE;'
 
|-style='vertical-align:top; background-color: #E8D7BE;'
|Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.12.6.1
+
|Valueset OID<!--vsValuesetOID-->: 2.16.840.1.113883.2.4.3.11.60.40.2.12.6.1
 +
|Binding<!--vsBindingTag-->:
 
|}
 
|}
 
{| class="wikitable"  width="60% "
 
{| class="wikitable"  width="60% "
 
|-style="background-color: #1F497D; color: white; font-weight: bold; "
 
|-style="background-color: #1F497D; color: white; font-weight: bold; "
|Conceptname
+
|Conceptname<!--vsConceptName-->
|Conceptcode
+
|Conceptcode<!--vsConceptCode-->
|Codesystem name||Codesystem OID
+
|Codesystem name<!--vsConceptSystemName-->||Codesystem OID<!--vsConceptSystemOID-->
|Description
+
|Description<!--vsDescription-->
 
|-style="vertical-align:top; "
 
|-style="vertical-align:top; "
 
|Rectal temperature
 
|Rectal temperature
|307047009
+
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=307047009 307047009]
 
|SNOMED CT
 
|SNOMED CT
 
|2.16.840.1.113883.6.96
 
|2.16.840.1.113883.6.96
Regel 238: Regel 241:
 
|-style="vertical-align:top; "
 
|-style="vertical-align:top; "
 
|Oral temperature
 
|Oral temperature
|415945006
+
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=415945006 415945006]
 
|SNOMED CT
 
|SNOMED CT
 
|2.16.840.1.113883.6.96
 
|2.16.840.1.113883.6.96
Regel 244: Regel 247:
 
|-style="vertical-align:top; "
 
|-style="vertical-align:top; "
 
|Axillary temperature
 
|Axillary temperature
|415882003
+
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=415882003 415882003]
 
|SNOMED CT
 
|SNOMED CT
 
|2.16.840.1.113883.6.96
 
|2.16.840.1.113883.6.96
Regel 250: Regel 253:
 
|-style="vertical-align:top; "
 
|-style="vertical-align:top; "
 
|Groin temperature
 
|Groin temperature
|415929009
+
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=415929009 415929009]
 
|SNOMED CT
 
|SNOMED CT
 
|2.16.840.1.113883.6.96
 
|2.16.840.1.113883.6.96
Regel 256: Regel 259:
 
|-style="vertical-align:top; "
 
|-style="vertical-align:top; "
 
|Tympanic temperature
 
|Tympanic temperature
|415974002
+
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=415974002 415974002]
 
|SNOMED CT
 
|SNOMED CT
 
|2.16.840.1.113883.6.96
 
|2.16.840.1.113883.6.96
Regel 262: Regel 265:
 
|-style="vertical-align:top; "
 
|-style="vertical-align:top; "
 
|Forehead temperature
 
|Forehead temperature
|415922000
+
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=415922000 415922000]
 
|SNOMED CT
 
|SNOMED CT
 
|2.16.840.1.113883.6.96
 
|2.16.840.1.113883.6.96
Regel 268: Regel 271:
 
|-style="vertical-align:top; "
 
|-style="vertical-align:top; "
 
|Temperature of vagina
 
|Temperature of vagina
|364246006
+
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=364246006 364246006]
 
|SNOMED CT
 
|SNOMED CT
 
|2.16.840.1.113883.6.96
 
|2.16.840.1.113883.6.96
Regel 274: Regel 277:
 
|-style="vertical-align:top; "
 
|-style="vertical-align:top; "
 
|Bladder temperature
 
|Bladder temperature
|698832009
+
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=698832009 698832009]
 
|SNOMED CT
 
|SNOMED CT
 
|2.16.840.1.113883.6.96
 
|2.16.840.1.113883.6.96
Regel 280: Regel 283:
 
|-style="vertical-align:top; "
 
|-style="vertical-align:top; "
 
|Core body temperature
 
|Core body temperature
|276885007
+
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=276885007 276885007]
 
|SNOMED CT
 
|SNOMED CT
 
|2.16.840.1.113883.6.96
 
|2.16.840.1.113883.6.96
Regel 286: Regel 289:
 
|}
 
|}
  
 
+
==This information model in other releases<!--ftOtherReleases-->==
==This information model in other releases==
+
<!-- Hieronder wordt een transclude page aangeroepen -->
<ul>
+
{{Versions-2.16.840.1.113883.2.4.3.11.60.40.3.12.6(EN)|2|2015}}
<li>[[BodyTemperature-v3.0(2016EN) | Release 2016, (Version 3.0)]]</li>
+
<!-- Tot hier de transclude page -->
<li>[[BodyTemperature-v3.1(2017EN) | Release 2017, (Version 3.1)]]</li>
+
==Information model references<!--ftReferences-->==
</ul>
+
====This information model refers to<!--ftRefersTo-->====
==More on this information model==
+
:--
 +
====This information model is used in<!--ftReferredBy-->====
 +
:--
 +
==Technical specifications in HL7v3 CDA and HL7 FHIR<!--ftHeader-->==
 
To exchange information based on health and care information models, additional, more technical specifications are required.<BR>
 
To exchange information based on health and care information models, additional, more technical specifications are required.<BR>
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:
+
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro-->
 
<ul>
 
<ul>
<li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2015bbr-?id=2.16.840.1.113883.2.4.3.11.60.5.4.2.12.6&effectiveDate=2015-04-01T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li>
+
<li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2015bbr-?id=2.16.840.1.113883.2.4.3.11.60.5.4.2.12.6&effectiveDate=2015-04-01T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li>
<li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR [https://simplifier.net/NictizSTU3/~resources?text=zib&category=StructureDefinition [[File:fhir.png|link=]]]</li>
+
<li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2015}}</li>
 
</ul>
 
</ul>
This information model is also available as [[Media:nl.nfu.BodyTemperature-v1.2.1(2015EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.nfu.BodyTemperature-v1.2.1(2015EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]]
+
==Downloads<!--ftDownloadTitle-->==
==About this information==
+
This information model is also available as [[Media:nl.nfu.BodyTemperature-v1.2.1(2015EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.nfu.BodyTemperature-v1.2.1(2015EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]]<!--ftDownloads-->
The information in this wikipage is based on ''Registratie aan de bron'' publication 2015 including errata dd. 16-07-2015 <BR>
+
==About this information<!--ftHeader2-->==
Conditions for use are located on the mainpage [[Bestand:list2.png|link=HCIM_Mainpage]]<BR>
+
The information in this wikipage is based on<!--ftInfoBase--> ''Registratie aan de bron'' publication 2015 including errata dd. 16-07-2015 <BR>
This page is generated on 24/01/2018 17:12:33 <BR>
+
Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR>
 +
This page is generated on 24/12/2018 12:29:53 with ZibExtraction v. 3.0.6932.1989<!--ftDate--> <BR>
 
-----
 
-----
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release_2015(EN)]] [[HCIM_Release_2015(EN) |Back to HCIM list ]]</div>
+
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2015(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2015(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div>

Huidige versie van 24 dec 2018 om 12:14


Attention!! This is not the most recent version of this information model. You can find the most recent version ''here''.

General information

Name: nl.nfu.BodyTemperature NL.png
Version: 1.2.1
HCIM Status:Final
Release: 2015
Release status: Published
Release date: 1-4-2015


Back 16.png Back to HCIM list

Metadata

DCM::CoderList Kerngroep Registratie aan de Bron
DCM::ContactInformation.Address *
DCM::ContactInformation.Name *
DCM::ContactInformation.Telecom *
DCM::ContentAuthorList Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron
DCM::CreationDate 12-11-2012
DCM::DeprecatedDate
DCM::DescriptionLanguage nl
DCM::EndorsingAuthority.Address
DCM::EndorsingAuthority.Name NFU
DCM::EndorsingAuthority.Telecom
DCM::Id 2.16.840.1.113883.2.4.3.11.60.40.3.12.6
DCM::KeywordList temperatuur, lichaamstemperatuur
DCM::LifecycleStatus Final
DCM::ModelerList Kerngroep Registratie aan de Bron
DCM::Name nl.nfu.Lichaamstemperatuur
DCM::PublicationDate 1-4-2015
DCM::PublicationStatus Published
DCM::ReviewerList Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron
DCM::RevisionDate 16-7-2015
DCM::Superseeds
DCM::Version 1.2.1
HCIM::PublicationLanguage EN

Revision History

Only available in Dutch

Publicatieversie 1.0 (15-02-2013)

Publicatieversie 1.1 (01-07-2013)

Publicatieversie 1.2 (01-04-2015)

ZIB-147 Aanpassingen in SNOMED CT codes en omschrijvingen voor codelijst TemperatuurMetingMethodeCodelijst n.a.v. review terminologie expert.
ZIB-276 In de klinische bouwsteen OverdrachtTemperatuur kwam de tagged value van concept TemperatuurMetingMethode niet overeen met de onderliggende waardenlijst.
ZIB-308 Prefix Overdracht weggehaald bij de generieke bouwstenen
ZIB-355 Naamgeving bouwsteen aanpassen.
ZIB-359 Aanpassen conceptnaam en waardelijst van het concept TemperatuurMetingMethode

Incl. algemene wijzigingsverzoeken:

ZIB-94 Aanpassen tekst van Disclaimer, Terms of Use & Copyrights
ZIB-154 Consequenties opsplitsing Medicatie bouwstenen voor overige bouwstenen.
ZIB-200 Naamgeving SNOMED CT in tagged values klinische bouwstenen gelijk getrokken.
ZIB-201 Naamgeving OID: in tagged value notes van klinische bouwstenen gelijk getrokken.
ZIB-309 EOI aangepast
ZIB-324 Codelijsten Name en Description beginnen met een Hoofdletter
ZIB-326 Tekstuele aanpassingen conform de kwaliteitsreview kerngroep 2015

Publicatieversie 1.2.1 (16-07-2015)

ZIB-419 Onjuiste SNOMED CT code in TemperatuurTypeCodelijst.

Concept

Measuring and documenting the body temperature of a person as a surrogate for a person’s central body temperature (the highest temperature at the centre of the torso)

Purpose

Measuring the body temperature is of medical importance. A number of diseases are accompanied by characteristic changes in body temperature. The symptoms of some diseases can be tracked by measuring the body temperature. The healthcare provider can use this temperature development to determine the effect of the treatment.

Information Model


#TemperatureTypeCodelist#9541#9544#9542#9543#9540BodyTemperature-v1.2.1Model(2015EN).png


Type Id Concept Card. Definition DefinitionCode Reference
Block.png NL-CM:12.6.1 Arrowdown.pngBodyTemperature Root concept of the BodyTemperature building block. This root concept contains all data elements of the BodyTemperature building block.
PQ.png NL-CM:12.6.2 Arrowright.pngTemperatureValue 1 Body temperature is the temperature inside the body, measured in °C (degrees Celsius). The measurement method must be specified for a correct interpretation of the measurement value.
386725007 Body temperature (observable entity)
TS.png NL-CM:12.6.4 Arrowright.pngTemperatureDateTime 1 Date and time of measurement.
ST.png NL-CM:12.6.3 Arrowright.pngExplanation 0..1 Comments or details that may be of importance in interpreting the measurement value.
CD.png NL-CM:12.6.5 Arrowright.pngTemperatureType 0..1 The anatomical location where the body temperature was measured.
List2.png TemperatureTypeCodelist

Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page List2.png

Example Instances

Only available in Dutch

Temperatuur DatumTijd TemperatuurWaarde Temperatuur Type Toelichting
08-02-2013 6:43 38,6 °C Tympanische temperatuur Voeten voelen heel koud aan

References

1. Parelsnoer DCM Lichaamstemperatuur v0.10 [Online] Beschikbaar op: http://www.nictiz.nl/uploaded/FILES/htmlcontent/dcm/parelsnoer/nl.parelsnoer.Lichaamstemperatuur.v0.10.pdf [Geraadpleegd: 23 februari 2015].

2. openEHR-EHR-OBSERVATION.temperature.v1[Online] Beschikbaar op: http://www.openehr.org/knowledge/ [Geraadpleegd: 23 februari 2015].

Valuesets

TemperatureTypeCodelist

Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.12.6.1 Binding:
Conceptname Conceptcode Codesystem name Codesystem OID Description
Rectal temperature 307047009 SNOMED CT 2.16.840.1.113883.6.96 Rectale temperatuur
Oral temperature 415945006 SNOMED CT 2.16.840.1.113883.6.96 Orale temperatuur (onder de tong)
Axillary temperature 415882003 SNOMED CT 2.16.840.1.113883.6.96 Axillaire temperatuur (onder de oksel)
Groin temperature 415929009 SNOMED CT 2.16.840.1.113883.6.96 Inguinale temperatuur (via de lies)
Tympanic temperature 415974002 SNOMED CT 2.16.840.1.113883.6.96 Tympanische temperatuur
Forehead temperature 415922000 SNOMED CT 2.16.840.1.113883.6.96 Temporale temperatuur
Temperature of vagina 364246006 SNOMED CT 2.16.840.1.113883.6.96 Vaginale temperatuur
Bladder temperature 698832009 SNOMED CT 2.16.840.1.113883.6.96 Blaastemperatuur
Core body temperature 276885007 SNOMED CT 2.16.840.1.113883.6.96 Kern temperatuur (invasief gemeten)

This information model in other releases

Information model references

This information model refers to

--

This information model is used in

--

Technical specifications in HL7v3 CDA and HL7 FHIR

To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:

  • HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment Artdecor.jpg
  • HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR Fhir.png

Downloads

This information model is also available as pdf file PDF.png or as spreadsheet Xlsx.png

About this information

The information in this wikipage is based on Registratie aan de bron publication 2015 including errata dd. 16-07-2015
Conditions for use are located on the mainpage List2.png
This page is generated on 24/12/2018 12:29:53 with ZibExtraction v. 3.0.6932.1989


Back 16.png Back to HCIM list