FallRiskForTransfer-v1.0(2015EN): verschil tussen versies
(Copy of) |
|||
Regel 1: | Regel 1: | ||
− | ==General information== | + | <!-- Hieronder wordt een transclude page aangeroepen --> |
− | Name: '''nl.nfu.FallRiskForTransfer''' [[Bestand:NL.png|link=OverdrachtValrisico-v1.0(2015NL)]]<BR> | + | {{Versions-2.16.840.1.113883.2.4.3.11.60.40.3.4.9(EN)|1|FallRiskForTransfer-v1.0(2015EN)}} |
− | Version: '''1.0''' <br> | + | <!-- Tot hier de transclude page --> |
− | HCIM Status:Final<br> | + | ==General information<!--hdGeneralInformation-->== |
− | Release: '''2015''' <br> | + | Name<!--hdName-->: '''nl.nfu.FallRiskForTransfer''' [[Bestand:NL.png|link=OverdrachtValrisico-v1.0(2015NL)]]<BR> |
− | Release status: Published<br> | + | Version<!--hdVersion-->: '''1.0''' <br> |
− | Release date: 8-9-2015 | + | HCIM Status<!--hdStatus-->:Final<br> |
+ | Release<!--hdPublication-->: '''2015''' <br> | ||
+ | Release status<!--hdPublicationStatus-->: Published<br> | ||
+ | Release date<!--hdPublicationDate-->: 8-9-2015 | ||
----- | ----- | ||
− | <div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= | + | <div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2015(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2015(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> |
==Metadata== | ==Metadata== | ||
Regel 61: | Regel 64: | ||
==Revision History== | ==Revision History== | ||
<div class="mw-collapsible mw-collapsed"> | <div class="mw-collapsible mw-collapsed"> | ||
− | ''Only available in Dutch'' | + | ''Only available in Dutch<!--noTranslation-->'' |
<u>Publicatieversie 1.0</u> (01-07-2015). | <u>Publicatieversie 1.0</u> (01-07-2015). | ||
Regel 75: | Regel 78: | ||
<BR> | <BR> | ||
<imagemap> Bestand:FallRiskForTransfer-v1.0Model(EN).png | center | <imagemap> Bestand:FallRiskForTransfer-v1.0Model(EN).png | center | ||
− | rect | + | rect 309 176 409 256 [[#8378]] |
− | rect | + | rect 202 59 341 129 [[#8392]] |
− | rect | + | rect 382 59 521 129 [[NursingIntervention-v1.0(2015EN)]] |
− | rect | + | rect 286 312 432 382 [[#8394]] |
desc none | desc none | ||
</imagemap> | </imagemap> | ||
Regel 84: | Regel 87: | ||
{| border= "1" width="1500px" style = "font-size: 9.5pt; border: solid 1px silver; border-collapse:collapse;" cellpadding = "3px" cellspacing ="0px" | {| border= "1" width="1500px" style = "font-size: 9.5pt; border: solid 1px silver; border-collapse:collapse;" cellpadding = "3px" cellspacing ="0px" | ||
|-style="background-color: #1F497D; color: white; font-weight: bold; font-variant: small-caps; " | |-style="background-color: #1F497D; color: white; font-weight: bold; font-variant: small-caps; " | ||
− | |style="width:30px;"|Type||style="width:100px;"|Id||colspan="6 " style="width:140px;"|Concept||Card.||style="width: 600px;"|Definition||style="width:200px;"|DefinitionCode||style="width:200px;"|Reference | + | |style="width:30px;"|Type<!--imType-->||style="width:100px;"|Id<!--imId-->||colspan="6 " style="width:140px;"|Concept<!--imConcept-->||Card.<!--imCard-->||style="width: 600px;"|Definition<!--imDefinition-->||style="width:200px;"|DefinitionCode<!--imDefinitionCode-->||style="width:200px;"|Reference<!--imReference--> |
|-style="vertical-align:top; background-color: #E3E3E3; " | |-style="vertical-align:top; background-color: #E3E3E3; " | ||
|style = "text-align:center" |[[Bestand: block.png| 20px | link=]] | |style = "text-align:center" |[[Bestand: block.png| 20px | link=]] | ||
Regel 94: | Regel 97: | ||
{| | {| | ||
|- | |- | ||
− | |<span | + | |<span title = "Codesystem: SNOMED CT>[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=129839007 129839007] At risk for falls</span> |
|} | |} | ||
| | | | ||
Regel 109: | Regel 112: | ||
{| | {| | ||
|- | |- | ||
− | |<span | + | |<span title = "Codesystem: SNOMED CT>[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=429557002 429557002] Moderate to high risk of</span> |
|} | |} | ||
| | | | ||
Regel 135: | Regel 138: | ||
{| | {| | ||
|- | |- | ||
− | |<span | + | |<span title = "Codesystem: LOINC>[https://terminologie.nictiz.nl/art-decor/loinc?conceptId=48767-8 48767-8] Annotation comment</span> |
|} | |} | ||
| | | | ||
|} | |} | ||
− | Columns Concept and DefinitionCode: hover over the values for more information<BR> | + | Columns Concept and DefinitionCode: hover over the values for more information<!--imHover--><BR> |
− | For explanation of the symbols, please see the legend page [[Bestand:list2.png|link=Legend]] | + | For explanation of the symbols, please see the legend page<!--imLegend--> [[Bestand:list2.png|link=Legend<!--wikiLegend-->]] |
==Example Instances== | ==Example Instances== | ||
− | ''Only available in Dutch'' | + | ''Only available in Dutch<!--noTranslation-->'' |
{|class="wikitable" width="553px" style= "font-size: 9.5pt;" | {|class="wikitable" width="553px" style= "font-size: 9.5pt;" | ||
Regel 163: | Regel 166: | ||
|} | |} | ||
− | ==This information model in other releases== | + | ==This information model in other releases<!--ftOtherReleases-->== |
− | < | + | <!-- Hieronder wordt een transclude page aangeroepen --> |
− | < | + | {{Versions-2.16.840.1.113883.2.4.3.11.60.40.3.4.9(EN)|2|2015}} |
− | + | <!-- Tot hier de transclude page --> | |
− | == | + | ==Information model references<!--ftReferences-->== |
+ | ====This information model refers to<!--ftRefersTo-->==== | ||
+ | *[[NursingIntervention-v1.0(2015EN)|NursingIntervention-v1.0]] | ||
+ | ====This information model is used in<!--ftReferredBy-->==== | ||
+ | :-- | ||
+ | ==Technical specifications in HL7v3 CDA and HL7 FHIR<!--ftHeader-->== | ||
To exchange information based on health and care information models, additional, more technical specifications are required.<BR> | To exchange information based on health and care information models, additional, more technical specifications are required.<BR> | ||
− | Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications: | + | Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro--> |
<ul> | <ul> | ||
− | <li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2015bbr-?id=2.16.840.1.113883.2.4.3.11.60.5.4.2.4.9&effectiveDate=2015-09-08T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li> | + | <li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2015bbr-?id=2.16.840.1.113883.2.4.3.11.60.5.4.2.4.9&effectiveDate=2015-09-08T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li> |
− | <li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR | + | <li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2015}}</li> |
</ul> | </ul> | ||
− | This information model is also available as [[Media:nl.nfu.FallRiskForTransfer-v1.0(2015EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.nfu.FallRiskForTransfer-v1.0(2015EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]] | + | ==Downloads<!--ftDownloadTitle-->== |
− | ==About this information== | + | This information model is also available as [[Media:nl.nfu.FallRiskForTransfer-v1.0(2015EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.nfu.FallRiskForTransfer-v1.0(2015EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]]<!--ftDownloads--> |
− | The information in this wikipage is based on ''Registratie aan de bron'' publication 2015 including errata dd. 16-07-2015 <BR> | + | ==About this information<!--ftHeader2-->== |
− | Conditions for use are located on the mainpage [[Bestand:list2.png|link=HCIM_Mainpage]]<BR> | + | The information in this wikipage is based on<!--ftInfoBase--> ''Registratie aan de bron'' publication 2015 including errata dd. 16-07-2015 <BR> |
− | This page is generated on | + | Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR> |
+ | This page is generated on 20/12/2018 12:42:12 with ZibExtraction v. 3.0.6928.22723<!--ftDate--> <BR> | ||
----- | ----- | ||
− | <div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= | + | <div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2015(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2015(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> |
Versie van 20 dec 2018 om 13:13
Inhoud
General information
Name: nl.nfu.FallRiskForTransfer
Version: 1.0
HCIM Status:Final
Release: 2015
Release status: Published
Release date: 8-9-2015
Metadata
DCM::CoderList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::ContactInformation.Address | * |
DCM::ContactInformation.Name | * |
DCM::ContactInformation.Telecom | * |
DCM::ContentAuthorList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::CreationDate | 13-3-2014 |
DCM::DeprecatedDate | |
DCM::DescriptionLanguage | nl |
DCM::EndorsingAuthority.Address | |
DCM::EndorsingAuthority.Name | NFU & V&VN |
DCM::EndorsingAuthority.Telecom | |
DCM::Id | 2.16.840.1.113883.2.4.3.11.60.40.3.4.9 |
DCM::KeywordList | Valrisico, vallen |
DCM::LifecycleStatus | Final |
DCM::ModelerList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::Name | nl.nfu.OverdrachtValrisico |
DCM::PublicationDate | 8-9-2015 |
DCM::PublicationStatus | Published |
DCM::ReviewerList | Projectgroep RadB Verpleegkundige Gegevens & Kerngroep Registratie aan de Bron |
DCM::RevisionDate | 8-9-2015 |
DCM::Superseeds | |
DCM::Version | 1.0 |
HCIM::PublicationLanguage | EN |
Revision History
Only available in Dutch
Publicatieversie 1.0 (01-07-2015).
Concept
Falling is the most common cause of damage resulting from accidents among seniors. Once a patient has fallen, they run a higher risk of falling again. The right approach can effectively reduce the risk of falling among seniors.
Purpose
Screening for the fall risk can determine the height of the risk. Recording an increased fall risk informs other healthcare providers of this risk. Preventative procedures can be implemented based on this information.
Information Model
Type | Id | Concept | Card. | Definition | DefinitionCode | Reference | |||||||
NL-CM:4.9.1 | FallRisk | Root concept of the FallRisk building block. This concept contains all data elements of the FallRisk building block. |
|
||||||||||
NL-CM:4.9.4 | IncreasedFallRisk | 1 | Indicator stating whether there is an increased risk of falling.
If the patient has fallen one or more times within the past six months, they have an increased risk of falling. |
|
|||||||||
NL-CM:4.9.3 | NursingProcedure | 0..* | The nursing procedures needed to reduce the fall risk and/or limit the effects of a potential fall. |
| |||||||||
NL-CM:4.9.2 | Explanation | 0..1 | The explanation of the fall risk or arguments supporting the determination of the increased fall risk. |
|
Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page
Example Instances
Only available in Dutch
Valrisico | |
VerhoogdValrisicoAanwezig | Ja |
VerpleegkundigeActie | |
Activiteit | Bed verlagen voor de nacht, nachtlampje aan. |
Toelichting | Patiënt is 's nachts gevallen bij uit bed stappen. |
This information model in other releases
Information model references
This information model refers to
This information model is used in
- --
Technical specifications in HL7v3 CDA and HL7 FHIR
To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:
- HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
- HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR
Downloads
This information model is also available as pdf file or as spreadsheet
About this information
The information in this wikipage is based on Registratie aan de bron publication 2015 including errata dd. 16-07-2015
Conditions for use are located on the mainpage
This page is generated on 20/12/2018 12:42:12 with ZibExtraction v. 3.0.6928.22723