BodyTemperature-v1.2.1(2015EN): verschil tussen versies
(Copy of) |
|||
Regel 297: | Regel 297: | ||
<ul> | <ul> | ||
<li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2015bbr-?id=2.16.840.1.113883.2.4.3.11.60.5.4.2.12.6&effectiveDate=2015-04-01T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li> | <li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2015bbr-?id=2.16.840.1.113883.2.4.3.11.60.5.4.2.12.6&effectiveDate=2015-04-01T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li> | ||
− | <li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR [https://simplifier.net/NictizSTU3/~resources?text=zib&category= | + | <li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR [https://simplifier.net/NictizSTU3/~resources?text=zib&category=Profile [[File:fhir.png|link=]]]</li> |
</ul> | </ul> | ||
This information model is also available as [[Media:nl.nfu.BodyTemperature-v1.2.1(2015EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.nfu.BodyTemperature-v1.2.1(2015EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]] | This information model is also available as [[Media:nl.nfu.BodyTemperature-v1.2.1(2015EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.nfu.BodyTemperature-v1.2.1(2015EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]] |
Versie van 20 feb 2018 om 10:04
Inhoud
General information
Name: nl.nfu.BodyTemperature
Version: 1.2.1
HCIM Status:Final
Release: 2015
Release status: Published
Release date: 1-4-2015
Metadata
DCM::CoderList | Kerngroep Registratie aan de Bron |
DCM::ContactInformation.Address | * |
DCM::ContactInformation.Name | * |
DCM::ContactInformation.Telecom | * |
DCM::ContentAuthorList | Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron |
DCM::CreationDate | 12-11-2012 |
DCM::DeprecatedDate | |
DCM::DescriptionLanguage | nl |
DCM::EndorsingAuthority.Address | |
DCM::EndorsingAuthority.Name | NFU |
DCM::EndorsingAuthority.Telecom | |
DCM::Id | 2.16.840.1.113883.2.4.3.11.60.40.3.12.6 |
DCM::KeywordList | temperatuur, lichaamstemperatuur |
DCM::LifecycleStatus | Final |
DCM::ModelerList | Kerngroep Registratie aan de Bron |
DCM::Name | nl.nfu.Lichaamstemperatuur |
DCM::PublicationDate | 1-4-2015 |
DCM::PublicationStatus | Published |
DCM::ReviewerList | Projectgroep Generieke Overdrachtsgegevens & Kerngroep Registratie aan de Bron |
DCM::RevisionDate | 16-7-2015 |
DCM::Superseeds | |
DCM::Version | 1.2.1 |
HCIM::PublicationLanguage | EN |
Revision History
Only available in Dutch
Publicatieversie 1.0 (15-02-2013)
Publicatieversie 1.1 (01-07-2013)
Publicatieversie 1.2 (01-04-2015)
ZIB-147 | Aanpassingen in SNOMED CT codes en omschrijvingen voor codelijst TemperatuurMetingMethodeCodelijst n.a.v. review terminologie expert. |
ZIB-276 | In de klinische bouwsteen OverdrachtTemperatuur kwam de tagged value van concept TemperatuurMetingMethode niet overeen met de onderliggende waardenlijst. |
ZIB-308 | Prefix Overdracht weggehaald bij de generieke bouwstenen |
ZIB-355 | Naamgeving bouwsteen aanpassen. |
ZIB-359 | Aanpassen conceptnaam en waardelijst van het concept TemperatuurMetingMethode |
Incl. algemene wijzigingsverzoeken:
ZIB-94 | Aanpassen tekst van Disclaimer, Terms of Use & Copyrights |
ZIB-154 | Consequenties opsplitsing Medicatie bouwstenen voor overige bouwstenen. |
ZIB-200 | Naamgeving SNOMED CT in tagged values klinische bouwstenen gelijk getrokken. |
ZIB-201 | Naamgeving OID: in tagged value notes van klinische bouwstenen gelijk getrokken. |
ZIB-309 | EOI aangepast |
ZIB-324 | Codelijsten Name en Description beginnen met een Hoofdletter |
ZIB-326 | Tekstuele aanpassingen conform de kwaliteitsreview kerngroep 2015 |
Publicatieversie 1.2.1 (16-07-2015)
ZIB-419 | Onjuiste SNOMED CT code in TemperatuurTypeCodelijst. |
Concept
Measuring and documenting the body temperature of a person as a surrogate for a person’s central body temperature (the highest temperature at the centre of the torso)
Purpose
Measuring the body temperature is of medical importance. A number of diseases are accompanied by characteristic changes in body temperature. The symptoms of some diseases can be tracked by measuring the body temperature. The healthcare provider can use this temperature development to determine the effect of the treatment.
Information Model
Type | Id | Concept | Card. | Definition | DefinitionCode | Reference | |||||||
NL-CM:12.6.1 | BodyTemperature | Root concept of the BodyTemperature building block. This root concept contains all data elements of the BodyTemperature building block. | |||||||||||
NL-CM:12.6.2 | TemperatureValue | 1 | Body temperature is the temperature inside the body, measured in °C (degrees Celsius). The measurement method must be specified for a correct interpretation of the measurement value. |
|
|||||||||
NL-CM:12.6.4 | TemperatureDateTime | 1 | Date and time of measurement. | ||||||||||
NL-CM:12.6.3 | Explanation | 0..1 | Comments or details that may be of importance in interpreting the measurement value. | ||||||||||
NL-CM:12.6.5 | TemperatureType | 0..1 | The anatomical location where the body temperature was measured. |
|
Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page
Example Instances
Only available in Dutch
Temperatuur DatumTijd | TemperatuurWaarde | Temperatuur Type | Toelichting |
08-02-2013 6:43 | 38,6 °C | Tympanische temperatuur | Voeten voelen heel koud aan |
References
1. Parelsnoer DCM Lichaamstemperatuur v0.10 [Online] Beschikbaar op: http://www.nictiz.nl/uploaded/FILES/htmlcontent/dcm/parelsnoer/nl.parelsnoer.Lichaamstemperatuur.v0.10.pdf [Geraadpleegd: 23 februari 2015].
2. openEHR-EHR-OBSERVATION.temperature.v1[Online] Beschikbaar op: http://www.openehr.org/knowledge/ [Geraadpleegd: 23 februari 2015].
Valuesets
TemperatureTypeCodelist
Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.12.6.1 |
Conceptname | Conceptcode | Codesystem name | Codesystem OID | Description |
Rectal temperature | 307047009 | SNOMED CT | 2.16.840.1.113883.6.96 | Rectale temperatuur |
Oral temperature | 415945006 | SNOMED CT | 2.16.840.1.113883.6.96 | Orale temperatuur (onder de tong) |
Axillary temperature | 415882003 | SNOMED CT | 2.16.840.1.113883.6.96 | Axillaire temperatuur (onder de oksel) |
Groin temperature | 415929009 | SNOMED CT | 2.16.840.1.113883.6.96 | Inguinale temperatuur (via de lies) |
Tympanic temperature | 415974002 | SNOMED CT | 2.16.840.1.113883.6.96 | Tympanische temperatuur |
Forehead temperature | 415922000 | SNOMED CT | 2.16.840.1.113883.6.96 | Temporale temperatuur |
Temperature of vagina | 364246006 | SNOMED CT | 2.16.840.1.113883.6.96 | Vaginale temperatuur |
Bladder temperature | 698832009 | SNOMED CT | 2.16.840.1.113883.6.96 | Blaastemperatuur |
Core body temperature | 276885007 | SNOMED CT | 2.16.840.1.113883.6.96 | Kern temperatuur (invasief gemeten) |
This information model in other releases
More on this information model
To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:
- HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
- HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR
This information model is also available as pdf file or as spreadsheet
About this information
The information in this wikipage is based on Registratie aan de bron publication 2015 including errata dd. 16-07-2015
Conditions for use are located on the mainpage
This page is generated on 24/01/2018 17:12:33