Attention!! This is not the most recent version of this information model. You can find the most recent version
''here''.
General information
Name: nl.zorg.BladderFunction
Version: 3.1
HCIM Status:Final
Release: 2018
Release status: Prepublished
Release date: 26-02-2019
Metadata
DCM::CoderList |
Werkgroep RadB Verpleegkundige Gegevens
|
DCM::ContactInformation.Address |
*
|
DCM::ContactInformation.Name |
*
|
DCM::ContactInformation.Telecom |
*
|
DCM::ContentAuthorList |
Werkgroep RadB Verpleegkundige Gegevens
|
DCM::CreationDate |
1-4-2014
|
DCM::DeprecatedDate |
|
DCM::DescriptionLanguage |
nl
|
DCM::EndorsingAuthority.Address |
|
DCM::EndorsingAuthority.Name |
PM
|
DCM::EndorsingAuthority.Telecom |
|
DCM::Id |
2.16.840.1.113883.2.4.3.11.60.40.3.4.14
|
DCM::KeywordList |
Mictie, continentie
|
DCM::LifecycleStatus |
Final
|
DCM::ModelerList |
Werkgroep RadB Verpleegkundige Gegevens
|
DCM::Name |
nl.zorg.Blaasfunctie
|
DCM::PublicationDate |
26-02-2019
|
DCM::PublicationStatus |
Prepublished
|
DCM::ReviewerList |
Projectgroep RadB Verpleegkundige Gegevens & Kerngroep Registratie aan de Bron
|
DCM::RevisionDate |
31-12-2017
|
DCM::Superseeds |
nl.zorg.Blaasfunctie-v3.0
|
DCM::Version |
3.1
|
HCIM::PublicationLanguage |
EN
|
Revision History
Only available in Dutch
Publicatieversie 1.0 (01-07-2015)
Publicatieversie 3.0 (01-05-2016)
Publicatieversie 3.1 (04-09-2017)
ZIB-530
|
Verwijzingen naar de bouwsteen Verpleegkundige Interventie verwijderd
|
ZIB-531
|
Vervangen 5-punts ICF schaal door 3-punts SNOMED CT schaal voor beperkingen en stoornissen
|
Concept
The primary function of the bladder is temporary storage of urine. A second important function of the bladder is secretion of the stored urine at the moment there is cause to do so. These functions can be disrupted due to various causes.
Purpose
Information on bladder function disorders is important in drawing up the nursing plan and for patient care. In a transfer situation, it offers the ability to anticipate the arrival of the patient and to achieve continuity in healthcare for the patient. This way, material or expertise can be coordinated beforehand, for example.
Evidence Base
The definitions of the concepts were (partially) taken from the ICF definitions.
Information Model
Type |
Id |
Concept |
Card. |
Definition |
DefinitionCode |
Reference
|
|
NL-CM:4.14.1
|
BladderFunction
|
|
Root concept of the BladderFunction information model. This root concept contains all data elements of the BladderFunction information model.
|
|
|
|
NL-CM:4.14.2
|
|
UrineContinence
|
0..1
|
Urine continence describes control over urine discharge. This includes disorders such as stress incontinence, urge incontinence, reflex incontinence, constant incontinence and mixed incontinence.
|
|
|
|
NL-CM:4.14.3
|
|
UrinaryStoma::Stoma
|
0..1
|
UrinaryStoma describes the presence of an unnatural, surgically created opening. If the patient has a urinary stoma, the date of placement, location of the stoma and any stoma pouches and an comment can be entered. The type of stoma is automatically a urinary stoma in this case.
|
|
|
|
NL-CM:4.14.4
|
|
UrineCatheter::MedicalDevice
|
0..1
|
UrineCatheter describes the presence of a urine catheter. If this is the case, the date of placement, urine catheter location, comment and catheter identification information can be described in addition to the type of catheter.
|
|
|
|
NL-CM:10.1.3
|
|
|
|
ProductType
|
|
A description of the type of catheter.
|
|
|
|
NL-CM:4.14.5
|
|
IncontinenceMaterial::MedicalDevice
|
0..1
|
A description of the incontinence material used.
|
|
|
|
NL-CM:4.14.6
|
|
Comment
|
0..1
|
Comment on the urinary (in)continence and treatment.
|
48767-8 Annotation comment [Interpretation] Narrative
|
|
|
Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page
Example Instances
Only available in Dutch
Blaasfunctie (urostoma)
|
UrineContinentie
|
-
|
Incontinentiemateriaal
|
-
|
Urostoma
|
StomaType
|
Urostoma
|
AanlegDatum
|
12-01-2014
|
Toelichting
|
Extra aandacht voor peristomale huid
|
UrineKatheter
|
ProductType
|
-
|
BeginDatum
|
-
|
Toelichting
|
-
|
|
Toelichting
|
Kan bij problemen contact opnemen met stomaverpleegkundige
|
Blaasfunctie (continentie stoornis)
|
UrineContinentie
|
Incontinent
|
Incontinentiemateriaal
|
-
|
Urostoma
|
Sinds
|
-
|
Opmerking bij urostoma
|
-
|
UrineKatheter
|
ProductType
|
Verblijfskatheter
|
BeginDatum
|
12-05-2014
|
Toelichting
|
-
|
|
Toelichting
|
Partner verzorgt insteekopening van katheter
|
References
1. International Classification of Functioning Disability and Health (ICF) [Online] Beschikbaar op:http:/www.rivm.nl/who-fic/icf.htm [Geraadpleegd: 13 februari 2015]
Valuesets
UrineCatheterTypeCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.4.14.2
|
Binding: Extensible
|
Conceptname
|
Conceptcode
|
Codesystem name |
Codesystem OID
|
Description
|
Indwelling urinary catheter
|
23973005
|
SNOMED CT
|
2.16.840.1.113883.6.96
|
Verblijfskatheter
|
Intermittent urethral drainage catheter, sterile
|
469715007
|
SNOMED CT
|
2.16.840.1.113883.6.96
|
Eenmalige katheter
|
Incontinence sheath
|
337636000
|
SNOMED CT
|
2.16.840.1.113883.6.96
|
Condoomkatheter
|
Suprapubic catheter
|
286861005
|
SNOMED CT
|
2.16.840.1.113883.6.96
|
Suprapubische katheter
|
JJ-stent
|
257366006
|
SNOMED CT
|
2.16.840.1.113883.6.96
|
Dubbel J catheter
|
Other
|
OTH
|
NullFlavor
|
2.16.840.1.113883.5.1008
|
Anders
|
UrineContinenceCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.4.14.1
|
Binding: Required
|
Conceptname
|
Conceptcode
|
Conceptvalue
|
Codesystem name |
Codesystem OID
|
Description
|
Urinary incontinence
|
165232002
|
0
|
SNOMED CT
|
2.16.840.1.113883.6.96
|
Incontinent
|
Bladder: occasional accident
|
165233007
|
1
|
SNOMED CT
|
2.16.840.1.113883.6.96
|
Af en toe een ongelukje (max. 1 keer per 24 uur)
|
Bladder: fully continent
|
165234001
|
2
|
SNOMED CT
|
2.16.840.1.113883.6.96
|
Continent (gedurende meer dan 7 dagen)
|
This information model in other releases
Information model references
This information model refers to
This information model is used in
- --
Technical specifications in HL7v3 CDA and HL7 FHIR
To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:
- HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
- HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR
Downloads
This information model is also available as pdf file or as spreadsheet
About this information
The information in this wikipage is based on Prerelease 2018-2
SNOMED CT and LOINC codes are based on:
- SNOMED Clinical Terms version: 20180731 [R] (July 2018 Release)
- LOINC version 2.64
Conditions for use are located on the mainpage
This page is generated on 12/03/2019 17:15:52 with ZibExtraction v. 3.0.7010.25883