DOSScore-v1.0(2018EN): verschil tussen versies

Uit Zorginformatiebouwstenen
Ga naar: navigatie, zoeken
(Nieuwe pagina aangemaakt met '<!-- Hieronder wordt een transclude page aangeroepen --> {{Versions-2.16.840.1.113883.2.4.3.11.60.40.3.18.7(EN)|1|DOSScore-v1.0(2018EN)}} <!-- Tot hier de transcl...')
 
 
(Een tussenliggende versie door dezelfde gebruiker niet weergegeven)
Regel 8: Regel 8:
 
Release<!--hdPublication-->: '''2018''' <br>
 
Release<!--hdPublication-->: '''2018''' <br>
 
Release status<!--hdPublicationStatus-->: Prepublished<br>
 
Release status<!--hdPublicationStatus-->: Prepublished<br>
Release date<!--hdPublicationDate-->: 01-10-2018
+
Release date<!--hdPublicationDate-->: 26-02-2019
 
-----
 
-----
 
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2018(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2018(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div>
 
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2018(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2018(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div>
Regel 47: Regel 47:
 
|style="width:250px; "|DCM::Name||nl.zorg.DOSScore
 
|style="width:250px; "|DCM::Name||nl.zorg.DOSScore
 
|-  
 
|-  
|style="width:250px; "|DCM::PublicationDate||01-10-2018
+
|style="width:250px; "|DCM::PublicationDate||26-02-2019
 
|-  
 
|-  
 
|style="width:250px; "|DCM::PublicationStatus||Prepublished
 
|style="width:250px; "|DCM::PublicationStatus||Prepublished
Regel 81: Regel 81:
 
==Information Model==
 
==Information Model==
 
<BR>
 
<BR>
<imagemap> Bestand:DOSScore-v1.0Model(EN).png | center  
+
<imagemap> Bestand:DOSScore-v1.0Model(2018EN).png | center  
rect 786 83 890 153 [[#11956]]
+
rect 787 43 891 113 [[#11956]]
rect 788 175 892 245 [[#11963]]
+
rect 789 135 893 205 [[#11963]]
rect 788 267 892 337 [[#11953]]
+
rect 789 227 893 297 [[#11953]]
rect 788 359 892 429 [[#11959]]
+
rect 789 319 893 389 [[#11959]]
rect 788 451 892 521 [[#11955]]
+
rect 789 411 893 481 [[#11955]]
rect 671 451 776 521 [[#11965]]
+
rect 672 411 777 481 [[#11965]]
rect 556 452 661 522 [[#11957]]
+
rect 557 412 662 482 [[#11957]]
rect 441 451 546 521 [[#11967]]
+
rect 442 411 547 481 [[#11967]]
rect 302 451 431 521 [[#11966]]
+
rect 303 411 432 481 [[#11966]]
rect 179 451 292 521 [[#11954]]
+
rect 180 411 293 481 [[#11954]]
rect 179 359 292 429 [[#11950]]
+
rect 180 319 293 389 [[#11950]]
rect 179 267 292 337 [[#11952]]
+
rect 180 227 293 297 [[#11952]]
rect 180 174 293 244 [[#11960]]
+
rect 181 134 294 204 [[#11960]]
rect 430 83 536 176 [[#11964]]
+
rect 431 43 537 136 [[#11964]]
rect 670 83 778 153 [[#11962]]
+
rect 671 43 779 113 [[#11962]]
rect 179 83 292 153 [[#11958]]
+
rect 180 43 293 113 [[#11958]]
rect 495 267 585 337 [[#11961]]
+
rect 496 227 586 297 [[#11961]]
 
desc none
 
desc none
 
</imagemap>
 
</imagemap>
Regel 416: Regel 416:
 
====This information model refers to<!--ftRefersTo-->====
 
====This information model refers to<!--ftRefersTo-->====
 
:--
 
:--
====This inforation model is used in<!--ftReferredBy-->====
+
====This information model is used in<!--ftReferredBy-->====
 
:--
 
:--
 
==Technical specifications in HL7v3 CDA and HL7 FHIR<!--ftHeader-->==
 
==Technical specifications in HL7v3 CDA and HL7 FHIR<!--ftHeader-->==
Regel 422: Regel 422:
 
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro-->
 
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro-->
 
<ul>
 
<ul>
<li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2018bbr-?id=2.16.840.1.113883.2.4.3.11.60.8.4.2.18.7&effectiveDate=2018-10-01T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li>
+
<li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2018bbr-?id=2.16.840.1.113883.2.4.3.11.60.8.4.2.18.7&effectiveDate=2019-02-26T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li>
 
<li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2018}}</li>
 
<li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2018}}</li>
 
</ul>
 
</ul>
Regel 428: Regel 428:
 
This information model is also available as [[Media:nl.zorg.DOSScore-v1.0(2018EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.zorg.DOSScore-v1.0(2018EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]]<!--ftDownloads-->
 
This information model is also available as [[Media:nl.zorg.DOSScore-v1.0(2018EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.zorg.DOSScore-v1.0(2018EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]]<!--ftDownloads-->
 
==About this information<!--ftHeader2-->==
 
==About this information<!--ftHeader2-->==
The information in this wikipage is based on<!--ftInfoBase--> Prerelease 2018 #1 <BR>
+
The information in this wikipage is based on<!--ftInfoBase--> Prerelease 2018-2 <BR>
 
SNOMED CT and LOINC codes are based on:
 
SNOMED CT and LOINC codes are based on:
 
<ul>
 
<ul>
Regel 435: Regel 435:
 
</ul>
 
</ul>
 
Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR>
 
Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR>
This page is generated on 01/11/2018 22:21:46 with ZibExtraction v. 2.0.6879.31307<!--ftDate--> <BR>
+
This page is generated on 12/03/2019 17:16:34 with ZibExtraction v. 3.0.7010.25883<!--ftDate--> <BR>
 
-----
 
-----
 
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2018(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2018(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div>
 
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2018(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2018(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div>

Huidige versie van 13 mrt 2019 om 00:52


Attention!! This is not the most recent version of this information model. You can find the most recent version ''here''.

General information

Name: nl.zorg.DOSScore NL.png
Version: 1.0
HCIM Status:Final
Release: 2018
Release status: Prepublished
Release date: 26-02-2019


Back 16.png Back to HCIM list

Metadata

DCM::CoderList Werkgroep RadB Verpleegkundige Gegevens
DCM::ContactInformation.Address *
DCM::ContactInformation.Name *
DCM::ContactInformation.Telecom *
DCM::ContentAuthorList Werkgroep RadB Verpleegkundige Gegevens
DCM::CreationDate 11-10-2016
DCM::DeprecatedDate
DCM::DescriptionLanguage nl
DCM::EndorsingAuthority.Address
DCM::EndorsingAuthority.Name
DCM::EndorsingAuthority.Telecom
DCM::Id 2.16.840.1.113883.2.4.3.11.60.40.3.18.7
DCM::KeywordList DOS, delier
DCM::LifecycleStatus Final
DCM::ModelerList Werkgroep RadB Verpleegkundige Gegevens
DCM::Name nl.zorg.DOSScore
DCM::PublicationDate 26-02-2019
DCM::PublicationStatus Prepublished
DCM::ReviewerList Projectgroep RadB Verpleegkundige Gegevens & Kerngroep Registratie aan de Bron
DCM::RevisionDate 31-12-2017
DCM::Superseeds
DCM::Version 1.0
HCIM::PublicationLanguage EN

Revision History

Only available in Dutch

Publicatieversie 1.0 (04-09-2017) .

Concept

The Delirium Observation Screening Scale is a tool to determine whether a patient has delirium. The DOSS includes 13 observations of behavior (verbal and non-verbal) which represent the symptoms of a delirium. These observations can be performed during regular contact with the patient.

Purpose

Delirium is one of the most forms of psychopathology among elderly patients and patients in the last phase of their lives. The main characteristic of delirium is the rapid onset and changing of symptoms. The DOSS is meant to qualify and quantify the nature and seriousness of delirium symptoms. This enables a quick start of treatment. The DOSS is used to signal risks and as an evaluation tool.

Evidence Base

The definitions of the concepts are based on the DOS score.

Information Model


#11956#11963#11953#11959#11955#11965#11957#11967#11966#11954#11950#11952#11960#11964#11962#11958#11961DOSScore-v1.0Model(2018EN).png


Type Id Concept Card. Definition DefinitionCode Reference
Block.png NL-CM:18.7.1 Arrowdown.pngDOSScore Root concept of the DOSScore information model. This root concept contains all data elements of the DOSScore information model.
INT.png NL-CM:18.7.3 Arrowright.pngDOSScoreTotal 0..1 Per shift a total score is calculated (minimum 0 and maximum 13). The total scores of three shifts (day, evening and night shifts) are summed to the total score of the day (minimum 0 and maximum 39).

The DOS scale final score is calculated by dividing the total score of the day by 3 (minimum 0 and maximum 13).

A DOS scale final score < 3 means that the patient is probably not delirious. A DOS scale final score > 3 means that the patiënt is probably delirious.

TS.png NL-CM:18.7.5 Arrowright.pngDOSScoreDateTime 1 The date on which the DOS score is registered.
INT.png NL-CM:18.7.6 Arrowright.pngDozesOff 0..1 DOS observation: patient dozes off during conversation or activities.

Score: 0: never 1: sometimes-always -: don't know

INT.png NL-CM:18.7.7 Arrowright.pngEasilyDistracted 0..1 DOS observation: patient is easily distracted by stimuli from the environment.

Someone is easily distracted by stimuli from the environment when he/she responds verbally or non-verbally to sounds or movements that have no relation to him/her and the nature of which does not make you expect a reaction from him/her.

Score: 0: never 1: sometimes-always -: don't know

INT.png NL-CM:18.7.8 Arrowright.pngMaintainsAttention 0..1 DOS observation: patient maintains attention to conversation or action.

Someone is maintaining attention to a conversation or action if he/she verbally or non-verbally shows that they are following the conversation or action.

Score: 1: never 0: sometimes-always -: don't know

INT.png NL-CM:18.7.9 Arrowright.pngUnfinishedQuestionAnswer 0..1 DOS observation: patient does not finish question or answer.

Score: 0: never 1: sometimes-always -: don't know

INT.png NL-CM:18.7.10 Arrowright.pngAnswersNoFit 0..1 DOS observation: patient gives answers that do not fit the question.

Score: 0: never 1: sometimes-always -: don't know

INT.png NL-CM:18.7.11 Arrowright.pngReactsSlowly 0..1 DOS observation: patient reacts slowly to instructions.

Someone reacts slowly to instructions when acting is delayed and/or there are moments of stillness/inactivity before moving into action.

Score: 0: never 1: sometimes-always -: don't know

INT.png NL-CM:18.7.12 Arrowright.pngThinksSomewhereElse 0..1 DOS observation: patient thinks they are somewhere else.

Someone thinks they are somewhere else when he/she shows this in words or actions.

Score: 0: never 1: sometimes-always -: don't know

INT.png NL-CM:18.7.13 Arrowright.pngKnowsPartDay 0..1 DOS observation: patient knows which part of the day it is.

Someone knows what part of the day it is when he/she shows such in words or actions.

Score: 1: never 0: sometimes-always -: don't know

INT.png NL-CM:18.7.14 Arrowright.pngRemembersRecent 0..1 DOS observation: patient remembers recent events.

Someone remembers recent events when he/she can for example tell whether they had visitors or what he/she ate.

Score: 1: never 0: sometimes-always -: don't know

INT.png NL-CM:18.7.15 Arrowright.pngRestless 0..1 DOS observation: patient is picking, disorderly, restless.

Score: 0: never 1: sometimes-always -: don't know

INT.png NL-CM:18.7.16 Arrowright.pngPullsWires 0..1 DOS observation: patient pulls IV tubing, feeding tubes, catheters, etc.

Score: 0: never 1: sometimes-always -: don't know

INT.png NL-CM:18.7.17 Arrowright.pngEasilyEmotional 0..1 DOS observation: patient is easily or suddenly emotional.

Someone is easily or suddenly emotional when he/she responds with a fierce emotion without provocation or when the fierceness of the emotion does not seem to match the provocation.

Score: 0: never 1: sometimes-always -: don't know

INT.png NL-CM:18.7.18 Arrowright.pngHallucinations 0..1 DOS observation: patient sees/hears things which are not there.

Someone sees/hears things which are not there when he/she shows this verbally (ask!) or non-verbally.

Score: 0: never 1: sometimes-always -: don't know

ST.png NL-CM:18.7.2 Arrowright.pngComment 0..1 Comment on the DOS score.
48767-8 Annotation comment [Interpretation] Narrative

Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page List2.png

Example Instances

Only available in Dutch

DOSScore
ZaktWeg 1
SnelAfgeleid 1
HeeftAandacht 0
VraagAntwoordNietAf -
AntwoordenNietPassend 1
ReageertTraag -
DenktErgensAnders 0
BeseftDagdeel 0
HerinnertRecent 0
Rusteloos 0
TrektDraden 0
SnelGeemotioneerd 1
Hallucinaties 0
DOSScoreDienst Dagdienst
DOSScoreTotaal 4
DOSScoreDatumTijd 19-12-2016 10:35
Toelichting -

This information model in other releases

Information model references

This information model refers to

--

This information model is used in

--

Technical specifications in HL7v3 CDA and HL7 FHIR

To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:

  • HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment Artdecor.jpg
  • HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR Fhir.png

Downloads

This information model is also available as pdf file PDF.png or as spreadsheet Xlsx.png

About this information

The information in this wikipage is based on Prerelease 2018-2
SNOMED CT and LOINC codes are based on:

  • SNOMED Clinical Terms version: 20180731 [R] (July 2018 Release)
  • LOINC version 2.64

Conditions for use are located on the mainpage List2.png
This page is generated on 12/03/2019 17:16:34 with ZibExtraction v. 3.0.7010.25883


Back 16.png Back to HCIM list