VisualFunction-v3.1(2017EN)
Inhoud
General information
Name: nl.zorg.VisualFunction
Version: 3.1
HCIM Status:Final
Publication: 2017
Release status: Prepublished
Publication date: 04-09-2017
Metadata
DCM::CoderList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::ContactInformation.Address | * |
DCM::ContactInformation.Name | * |
DCM::ContactInformation.Telecom | * |
DCM::ContentAuthorList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::CreationDate | 4-4-2014 |
DCM::DeprecatedDate | |
DCM::DescriptionLanguage | nl |
DCM::EndorsingAuthority.Address | |
DCM::EndorsingAuthority.Name | PM |
DCM::EndorsingAuthority.Telecom | |
DCM::Id | 2.16.840.1.113883.2.4.3.11.60.40.3.4.16 |
DCM::KeywordList | Zien, lagere visuele functies, gezichtsvermogen |
DCM::LifecycleStatus | Final |
DCM::ModelerList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::Name | nl.zorg.FunctieZien |
DCM::PublicationDate | 04-09-2017 |
DCM::PublicationStatus | Prepublished |
DCM::ReviewerList | Projectgroep RadB Verpleegkundige Gegevens & Kerngroep Registratie aan de Bron |
DCM::RevisionDate | 04-09-2017 |
DCM::Superseeds | nl.zorg.FunctieZien-v3.0 |
DCM::Version | 3.1 |
HCIM::PublicationLanguage | EN |
Revision History
Only available in Dutch
Publicatieversie 1.0 (01-07-2015)
Publicatieversie 3.0 (01-05-2016)
Publicatieversie 3.1 (04-09-2017)
ZIB-530 | Verwijzingen naar de bouwsteen Verpleegkundige Interventie verwijderd |
ZIB-531 | Vervangen 5-punts ICF schaal door 3-punts SNOMED CT schaal voor beperkingen en stoornissen |
.
Concept
Sight is the ability to observe lit objects, with the goal of orienting yourself on objects and people in a lit environment. This pertains to observing the light stimuli, and not processing them in the brain.
A sight disorder can lead to things including orientation problems.
Purpose
Information on visual function disorders is important in patient care and treatment and particularly in the communication with the patient. Based on this information, healthcare can be adjusted to the patient’s limitations if needed.
Evidence Base
The definitions of the concepts were (partially) taken from the ICNP definitions.
Information Model
Type | Id | Concept | Card. | Definition | DefinitionCode | Reference | ||||||||
NL-CM:4.16.1 | VisualFunction | Root concept of the VisualFunction information model. This concept contains all data elements of the VisualFunction information model. | ||||||||||||
NL-CM:4.16.3 | VisualFunction | 1 | The ability to see as a result of response to stimuli of visual organs |
|
| |||||||||
NL-CM:4.16.4 | VisualAid:MedicalDevice | 0..* | The medical aids used to support the visual function. |
|
| |||||||||
NL-CM:10.1.3 | ProductType | The type of product used to help the patient see. |
| |||||||||||
NL-CM:4.16.2 | Comment | 0..1 | A comment on the visual function. |
|
Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page
Example Instances
Only available in Dutch
FunctieZien | |
VisueleFunctie | Verminderd gezichtsvermogen |
ZienHulpmiddel | |
ProductType | Leesbril |
Toelichting | Ziet met linkeroog slechter dan met het rechteroog. |
References
1. International Classification of Functioning Disability and Health (ICF) [Online] Beschikbaar op:http:/www.rivm.nl/who-fic/icf.htm [Geraadpleegd: 13 februari 2015]
Valuesets
VisualAidTypeCodelist
Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.4.16.2 |
Conceptname | Conceptcode | Codesystem name | Codesystem OID | Description |
geen | 0 | eCare codes | 2.16.840.1.113883.2.4.3.11.22.218 | geen visuele hulpmiddelen |
single vision reading glasses | 423013001 | SNOMED CT | 2.16.840.1.113883.6.96 | leesbril |
eye glasses | 50121007 | SNOMED CT | 2.16.840.1.113883.6.96 | bril |
contact lenses | 57368009 | SNOMED CT | 2.16.840.1.113883.6.96 | contactlenzen |
magnifier | 264865009 | SNOMED CT | 2.16.840.1.113883.6.96 | loep |
other | OTH | NullFlavor | 2.16.840.1.113883.5.1008 | anders |
VisualFunctionCodelist
Valueset OID 2.16.840.1.113883.2.4.3.11.60.40.2.4.16.1 |
Conceptname | Conceptcode | Codesystem name | Codesystem OID | Description |
Normal vision | 45089002 | SNOMED CT | 2.16.840.1.113883.6.96 | Geen visuele stoornis |
Visual impairment | 397540003 | SNOMED CT | 2.16.840.1.113883.6.96 | Verminderd gezichtsvermogen |
Blind or low vision | 267727004 | SNOMED CT | 2.16.840.1.113883.6.96 | (Vrijwel) blind |
More on this information model
More technical information and HL7/XML documentation you can find on the Nictiz Art-Decor page about this information model[1]
This information model is also available as pdf file or as spreadsheet
About this information
The information in this wikipage is based on Prerelease 2017 #1
Conditions for use are located on the mainpage
This page is generated on 21/09/2017 18:24:49