NutritionAdvice-v3.2(2019EN): verschil tussen versies
(Nieuwe pagina aangemaakt met '<!-- Hieronder wordt een transclude page aangeroepen --> {{Versions-2.16.840.1.113883.2.4.3.11.60.40.3.7.11(EN)|1|NutritionAdvice-v3.2(2019EN)}} <!-- Tot hier de...') |
(geen verschil)
|
Versie van 7 jul 2019 om 23:23
Inhoud
General information
Name: nl.zorg.NutritionAdvice
Version: 3.2
HCIM Status:Final
Release: 2019
Release status: Prepublished
Release date: 06-07-2019
Metadata
DCM::CoderList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::ContactInformation.Address | * |
DCM::ContactInformation.Name | * |
DCM::ContactInformation.Telecom | * |
DCM::ContentAuthorList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::CreationDate | 12-2-2014 |
DCM::DeprecatedDate | |
DCM::DescriptionLanguage | nl |
DCM::EndorsingAuthority.Address | |
DCM::EndorsingAuthority.Name | PM |
DCM::EndorsingAuthority.Telecom | |
DCM::Id | 2.16.840.1.113883.2.4.3.11.60.40.3.7.11 |
DCM::KeywordList | Voedingsadvies, dieet, consistentie |
DCM::LifecycleStatus | Final |
DCM::ModelerList | Werkgroep RadB Verpleegkundige Gegevens |
DCM::Name | nl.zorg.Voedingsadvies |
DCM::PublicationDate | 06-07-2019 |
DCM::PublicationStatus | Prepublished |
DCM::ReviewerList | Projectgroep RadB Verpleegkundige Gegevens & Kerngroep Registratie aan de Bron |
DCM::RevisionDate | 28-05-2019 |
DCM::Superseeds | nl.zorg.Voedingsadvies-v3.1 |
DCM::Version | 3.2 |
HCIM::PublicationLanguage | EN |
Revision History
Only available in Dutch
Publicatieversie 1.0 (01-07-2015)
Publicatieversie 3.0 (01-05-2016)
Publicatieversie 3.1 (04-09-2017)
ZIB-530 | Verwijzingen naar de bouwsteen Verpleegkundige Interventie verwijderd |
ZIB-549 | De Engelse naam van de bouwsteen en het rootconcept zijn niet correct |
ZIB-569 | Concept beschrijving ontbreekt in de Engelstalige versie |
Publicatieversie 3.2 (06-07-2019)
ZIB-707 | Geen indicatie mogelijk bij zib Voedingsadvies |
Concept
A nutritional advice is a description of nourishment for the patient, which must meet specific requirements in view of the health condition of the patient. Allergies and food intolerances or chewing and swallowing problems may be a reason for special nutrition.
Purpose
Recording and communicating nutrition advice provides insight in policy regarding the patient’s diet. If this information is not available, it can lead to unsafe situations for the patient.
Especially in transfer cases, it is important for nutrition advices to be clearly communicated.
Information Model
Type | Id | Concept | Card. | Definition | DefinitionCode | Reference | ||||||||
NL-CM:7.11.1 | NutritionAdvice | Root concept of the NutritionAdvice information model. This concept contains all data elements of the NutritionAdvice information model. |
|
|||||||||||
NL-CM:7.11.2 | DietType | 0..1 | Description of the type of diet. |
|
||||||||||
NL-CM:7.11.3 | Consistency | 0..1 | A description of the consistency of the food. |
|
||||||||||
NL-CM:7.11.5 | Indication::Problem | 0..1 | The indication is the reason for advising the diet |
|
| |||||||||
NL-CM:7.11.4 | Comment | 0..1 | A comment on the nutrition advice. |
|
Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page
Example Instances
Only available in Dutch
Voedingsadvies | |
DieetType | Energie verrijkt |
Consistentie | Dikvloeibaar |
Toelichting | Sinds een week dieet veranderd in energieverrijkt. |
This information model in other releases
- Release 2015, (Version 1.0)
- Release 2016, (Version 3.0)
- Release 2017, (Version 3.1)
- Prerelease 2018-2, (Version 3.1)
- Release 2020, (Version 3.2)
- Prerelease 2021-2, (Version 3.2)
- Prerelease 2022-1, (Version 3.2)
- Prerelease 2023-1, (Version 3.2.1)
- Prerelease 2024-1, (Version 3.2.1)
Information model references
This information model refers to
- --
This information model is used in
Technical specifications in HL7v3 CDA and HL7 FHIR
To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:
- HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
- HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR
Downloads
This information model is also available as pdf file or as spreadsheet
About this information
The information in this wikipage is based on Prerelease 2019-1
SNOMED CT and LOINC codes are based on:
- SNOMED Clinical Terms version: 20190131 [R] (January 2019 Release)
- LOINC version 2.64
Conditions for use are located on the mainpage
This page is generated on 07/07/2019 11:31:43 with ZibExtraction v. 3.0.7127.3724