Refraction-v1.0(2020EN): verschil tussen versies
(Nieuwe pagina aangemaakt met '<!-- Hieronder wordt een transclude page aangeroepen --> {{Versions-2.16.840.1.113883.2.4.3.11.60.40.3.12.20(EN)|1|Refraction-v1.0(2020EN)}} <!-- Tot hier de tran...') |
(→Technical specifications in HL7v3 CDA and HL7 FHIR) |
||
(2 tussenliggende versies door een andere gebruiker niet weergegeven) | |||
Regel 25: | Regel 25: | ||
|style="width:250px; "|DCM::ContentAuthorList||* | |style="width:250px; "|DCM::ContentAuthorList||* | ||
|- | |- | ||
− | |style="width:250px; "|DCM::CreationDate|| | + | |style="width:250px; "|DCM::CreationDate||17-5-2020 |
|- | |- | ||
|style="width:250px; "|DCM::DeprecatedDate|| | |style="width:250px; "|DCM::DeprecatedDate|| | ||
Regel 113: | Regel 113: | ||
{| | {| | ||
|- | |- | ||
− | |<span title = "Codesystem: SNOMED CT (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251718005 251718005] Refractive power</span> | + | |<span title = "Codesystem: SNOMED CT; Refractiesterkte (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251718005 251718005] Refractive power</span> |
|} | |} | ||
| | | | ||
Regel 166: | Regel 166: | ||
{| | {| | ||
|- | |- | ||
− | |<span title = "Codesystem: SNOMED CT (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251797004 251797004] Power of cylinder</span> | + | |<span title = "Codesystem: SNOMED CT; Cillindersterkte (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251797004 251797004] Power of cylinder</span> |
|} | |} | ||
| | | | ||
Regel 180: | Regel 180: | ||
{| | {| | ||
|- | |- | ||
− | |<span title = "Codesystem: SNOMED CT (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251799001 251799001] Axis of cylinder</span> | + | |<span title = "Codesystem: SNOMED CT; As van cilinder (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251799001 251799001] Axis of cylinder</span> |
|} | |} | ||
| | | | ||
Regel 189: | Regel 189: | ||
|colspan ="5" style ="padding-left: 0px"|<span Id=14355 Title="NL: Prisma">[[Bestand: arrowdown.png | 10px | link=]]Prisma</span> | |colspan ="5" style ="padding-left: 0px"|<span Id=14355 Title="NL: Prisma">[[Bestand: arrowdown.png | 10px | link=]]Prisma</span> | ||
|0..1 | |0..1 | ||
− | |Container of the Prisma concept.This container contains all data elements of the Prisma | + | |Container of the Prisma concept.This container contains all data elements of the Prisma container. |
| | | | ||
| | | | ||
Regel 204: | Regel 204: | ||
{| | {| | ||
|- | |- | ||
− | |<span title = "Codesystem: SNOMED CT (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251762001 251762001] Prism strength</span> | + | |<span title = "Codesystem: SNOMED CT; Prismasterkte (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251762001 251762001] Prism strength</span> |
|} | |} | ||
| | | | ||
Regel 219: | Regel 219: | ||
{| | {| | ||
|- | |- | ||
− | |<span title = "Codesystem: SNOMED CT (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=246223004 246223004] Prism base direction</span> | + | |<span title = "Codesystem: SNOMED CT; Richting van basis van prisma (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=246223004 246223004] Prism base direction</span> |
|} | |} | ||
| | | | ||
Regel 226: | Regel 226: | ||
||NL-CM:12.20.14 | ||NL-CM:12.20.14 | ||
|style = "width: 7px; padding-left: 0px; padding-right: 0px; border-left: none; border-right: 1px dotted silver;" | | |style = "width: 7px; padding-left: 0px; padding-right: 0px; border-left: none; border-right: 1px dotted silver;" | | ||
− | |colspan ="5" style ="padding-left: 0px"|<span Id=14351 Title="NL: SferischeRefractie">[[Bestand: arrowdown.png | 10px | link=]] | + | |colspan ="5" style ="padding-left: 0px"|<span Id=14351 Title="NL: SferischeRefractie">[[Bestand: arrowdown.png | 10px | link=]]SfericRefraction</span> |
|0..1 | |0..1 | ||
− | |Container of the | + | |Container of the SfericRefraction concept.This container contains all data elements of the SfericRefraction concept. |
| | | | ||
| | | | ||
Regel 238: | Regel 238: | ||
|colspan ="4" style ="padding-left: 0px"|<span Id=14349 Title="NL: SferischeRefractieWaarde">[[Bestand: arrowright.png | 10px | link=]]SfericRefractionValue</span> | |colspan ="4" style ="padding-left: 0px"|<span Id=14349 Title="NL: SferischeRefractieWaarde">[[Bestand: arrowright.png | 10px | link=]]SfericRefractionValue</span> | ||
|1 | |1 | ||
− | |The spherical spectacle strength power needed to correct | + | |The spherical spectacle strength power needed to correct nearsightedness (myopia) or farsightedness (hyperopia), expressed in diopters, ascending by 0.25D. |
| | | | ||
{| | {| | ||
|- | |- | ||
− | |<span title = "Codesystem: SNOMED CT (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251795007 251795007] Power of sphere</span> | + | |<span title = "Codesystem: SNOMED CT; Sferische sterkte (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251795007 251795007] Power of sphere</span> |
|} | |} | ||
| | | | ||
Regel 265: | Regel 265: | ||
{| | {| | ||
|- | |- | ||
− | |<span title = "Codesystem: SNOMED CT (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251718005 251718005] Refractive power</span> | + | |<span title = "Codesystem: SNOMED CT; Refractiesterkte (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251718005 251718005] Refractive power</span> |
|} | |} | ||
| | | | ||
Regel 438: | Regel 438: | ||
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro--> | Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro--> | ||
<ul> | <ul> | ||
− | <li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2020bbr-?id=2.16.840.1.113883.2.4.3.11.60. | + | <li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2020bbr-?id=2.16.840.1.113883.2.4.3.11.60.121.4.2.12.20&effectiveDate=2020-09-01T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li> |
− | <li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2020}}</li> | + | <li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2020|Refraction}}</li> |
</ul> | </ul> | ||
+ | |||
==Downloads<!--ftDownloadTitle-->== | ==Downloads<!--ftDownloadTitle-->== | ||
This information model is also available as [[Media:nl.zorg.Refraction-v1.0(2020EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.zorg.Refraction-v1.0(2020EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]]<!--ftDownloads--> | This information model is also available as [[Media:nl.zorg.Refraction-v1.0(2020EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.zorg.Refraction-v1.0(2020EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]]<!--ftDownloads--> | ||
Regel 447: | Regel 448: | ||
SNOMED CT and LOINC codes are based on: | SNOMED CT and LOINC codes are based on: | ||
<ul> | <ul> | ||
− | <li>SNOMED Clinical Terms version: | + | <li>SNOMED Clinical Terms version: 20200731 [R] (July 2020 Release)</li> |
<li>LOINC version 2.67</li> | <li>LOINC version 2.67</li> | ||
</ul> | </ul> | ||
Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR> | Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR> | ||
− | This page is generated on | + | This page is generated on 29/09/2020 21:24:19 with ZibExtraction v. 4.0.7577.31095<!--ftDate--> <BR> |
----- | ----- | ||
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2020(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2020(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> | <div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2020(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2020(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div> |
Huidige versie van 8 dec 2023 om 11:54
Inhoud
- 1 General information
- 2 Metadata
- 3 Revision History
- 4 Concept
- 5 Purpose
- 6 Patient Population
- 7 Information Model
- 8 Example Instances
- 9 Valuesets
- 10 This information model in other releases
- 11 Information model references
- 12 Technical specifications in HL7v3 CDA and HL7 FHIR
- 13 Downloads
- 14 About this information
General information
Name: nl.zorg.Refraction
Version: 1.0
HCIM Status:Final
Release: 2020
Release status: Published
Release date: 01-09-2020
Metadata
DCM::CoderList | * |
DCM::ContactInformation.Address | * |
DCM::ContactInformation.Name | * |
DCM::ContactInformation.Telecom | * |
DCM::ContentAuthorList | * |
DCM::CreationDate | 17-5-2020 |
DCM::DeprecatedDate | |
DCM::DescriptionLanguage | nl |
DCM::EndorsingAuthority.Address | |
DCM::EndorsingAuthority.Name | * |
DCM::EndorsingAuthority.Telecom | |
DCM::Id | 2.16.840.1.113883.2.4.3.11.60.40.3.12.20 |
DCM::KeywordList | |
DCM::LifecycleStatus | Final |
DCM::ModelerList | * |
DCM::Name | nl.zorg.Refractie |
DCM::PublicationDate | 01-09-2020 |
DCM::PublicationStatus | Published |
DCM::ReviewerList | |
DCM::RevisionDate | |
DCM::Supersedes | * |
DCM::Version | 1.0 |
HCIM::PublicationLanguage | EN |
Revision History
Only available in Dutch
Publicatieversie 1.0 (01-09-2020).
Concept
The refraction measurement is a measurement with which the refractive error of the eye is determined. During the refraction measurement, the necessary correction is established: the spherical power (in diopter), the cylindrical power (in diopter), the axis direction(in degrees) for any cylindrical correction, the prism (in diopter)and any additional power of the reading area (in diopter), the so-called reading addition
Purpose
The purpose of a refraction measurement is to determine the correction (through glasses or lenses) with which the patient can see optimally.
Patient Population
Adults and children from the age that they can interpret a picture chart.
Information Model
Type | Id | Concept | Card. | Definition | DefinitionCode | Reference | ||||||||
NL-CM:12.20.1 | Refraction | Root concept of the Refractie information model.This root concept contains all data elements of the Refraction information model. |
|
|||||||||||
NL-CM:12.20.4 | RefractionMeasurementMethod | 0..1 | The method used to measure the refraction. |
|
| |||||||||
NL-CM:12.20.3 | RefractionDateTime | 0..1 | The date and time when the refraction measurement was carried out. |
|
||||||||||
NL-CM:12.20.12 | CilindricalRefraction | 0..1 | Container of the CilindricalRefraction concept.This container contains all data elements of the CilindricalRefraction concept. | |||||||||||
NL-CM:12.20.11 | CylindricalRefractionValue | 1 | The power of the cylinder needed to correct the cylindrical error (astigmatism), expressed in diopters. When a cylindrical refraction is registered, the axis of the cylinder must also be specified. |
|
||||||||||
NL-CM:12.20.13 | CilindricRefractionAxis | 1 | The axis direction of the cylindrical refraction value expressed in degrees. |
|
||||||||||
NL-CM:12.20.5 | Prisma | 0..1 | Container of the Prisma concept.This container contains all data elements of the Prisma container. | |||||||||||
NL-CM:12.20.6 | PrismaValue | 1 | The power of the prism, expressed in diopters. |
|
||||||||||
NL-CM:12.20.7 | PrismaBase | 1 | The base of the prism, expressed in degrees. |
|
||||||||||
NL-CM:12.20.14 | SfericRefraction | 0..1 | Container of the SfericRefraction concept.This container contains all data elements of the SfericRefraction concept. | |||||||||||
NL-CM:12.20.9 | SfericRefractionValue | 1 | The spherical spectacle strength power needed to correct nearsightedness (myopia) or farsightedness (hyperopia), expressed in diopters, ascending by 0.25D. |
|
||||||||||
NL-CM:12.20.10 | SfericalEquivalent | 0..1 | The spherical power added to half of the cylindrical power. Expressed in diopters, ascending by 0.1D. Some equipment automatically calculates the spherical equivalent automatically. | |||||||||||
NL-CM:12.20.8 | ReadAddition | 0..1 | A supplement that is added to the refraction value to determine the strength of the reading glasses, expressed in diopters. |
|
||||||||||
NL-CM:12.20.2 | AnatomicalLocation | 0..1 | The laterality of the eye whose of which the refraction has been measured. |
|
| |||||||||
NL-CM:12.20.15 | Laterality | Laterality adds information about body site to the anatomic location, e.g. left. |
|
Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page
Example Instances
Only available in Dutch
Refractie DatumTijd | Refractie Methode | Refractie Lateraliteit | Prisma | Cilindrische Refractie | Sferisch Equivalent | Lees Additie | |||
Waarde | Basis | Waarde | As | Equivalent | Waarde | ||||
01-01-2020 | Objectieve refractie | Rechts | 2.00 | 90 | -0.75 | 900 | +0.63 | +1.00 | +2.00 |
01-01-2020 | Objectieve refractie | Links | 1.50 | 45 | -1.00 | 00 | 0 | +0.5 | +2.00 |
12-01-2020 |
Subjectieve refractie | Rechts | -- | -- | -- | -- | -- | +1.50 | -- |
12-01-2020 |
Subjectieve refractie | Links | -- | -- | -- | -- | -- | +2.00 | -- |
Valuesets
LateralityCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.12.20.2 | Binding: Required |
Conceptname | Conceptcode | Codesystem name | Codesystem OID | Description |
Left | 7771000 | SNOMED CT | 2.16.840.1.113883.6.96 | Links |
Right | 24028007 | SNOMED CT | 2.16.840.1.113883.6.96 | Rechts |
RefractionMeasurementMethodCodelist
Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.12.20.1 | Binding: Extensible |
Conceptname | Conceptcode | Codesystem name | Codesystem OID | Description |
Subjective refraction | 397277005 | SNOMED CT | 2.16.840.1.113883.6.96 | Subjectieve refractie |
Objective refraction | 397276001 | SNOMED CT | 2.16.840.1.113883.6.96 | Objectieve refractie |
This information model in other releases
- Prerelease 2021-2, (Version 1.1)
- Prerelease 2022-1, (Version 1.2)
- Prerelease 2023-1, (Version 2.0)
- Prerelease 2024-1, (Version 2.0)
Information model references
This information model refers to
This information model is used in
- --
Technical specifications in HL7v3 CDA and HL7 FHIR
To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:
- HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment
- HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR
Downloads
This information model is also available as pdf file or as spreadsheet
About this information
The information in this wikipage is based on Release 2020
SNOMED CT and LOINC codes are based on:
- SNOMED Clinical Terms version: 20200731 [R] (July 2020 Release)
- LOINC version 2.67
Conditions for use are located on the mainpage
This page is generated on 29/09/2020 21:24:19 with ZibExtraction v. 4.0.7577.31095