FeedingTubeSystem-v3.2(2018EN): verschil tussen versies

Uit Zorginformatiebouwstenen
Ga naar: navigatie, zoeken
(Nieuwe pagina aangemaakt met '<!-- Hieronder wordt een transclude page aangeroepen --> {{Versions-2.16.840.1.113883.2.4.3.11.60.40.3.10.3(EN)|1|FeedingTubeSystem-v3.2(2018EN)}} <!-- Tot hier d...')
 
 
Regel 8: Regel 8:
 
Release<!--hdPublication-->: '''2018''' <br>
 
Release<!--hdPublication-->: '''2018''' <br>
 
Release status<!--hdPublicationStatus-->: Prepublished<br>
 
Release status<!--hdPublicationStatus-->: Prepublished<br>
Release date<!--hdPublicationDate-->: 01-10-2018
+
Release date<!--hdPublicationDate-->: 26-02-2019
 
-----
 
-----
 
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2018(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2018(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div>
 
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2018(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2018(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div>
Regel 47: Regel 47:
 
|style="width:250px; "|DCM::Name||nl.zorg.SondeSysteem
 
|style="width:250px; "|DCM::Name||nl.zorg.SondeSysteem
 
|-  
 
|-  
|style="width:250px; "|DCM::PublicationDate||01-10-2018
+
|style="width:250px; "|DCM::PublicationDate||26-02-2019
 
|-  
 
|-  
 
|style="width:250px; "|DCM::PublicationStatus||Prepublished
 
|style="width:250px; "|DCM::PublicationStatus||Prepublished
Regel 110: Regel 110:
 
==Information Model==
 
==Information Model==
 
<BR>
 
<BR>
<imagemap> Bestand:FeedingTubeSystem-v3.2Model(EN).png | center  
+
<imagemap> Bestand:FeedingTubeSystem-v3.2Model(2018EN).png | center  
rect 591 167 731 237 [[#12057]]
+
rect 559 161 699 231 [[#12057]]
rect 211 305 351 375 [[MedicalDevice-v3.1.1(2018EN)]]
+
rect 179 299 319 369 [[MedicalDevice-v3.2(2018EN)]]
rect 211 49 351 119 [[#12055]]
+
rect 179 43 319 113 [[#12055]]
rect 626 305 716 375 [[#12051]]
+
rect 594 299 684 369 [[#12051]]
rect 610 423 734 473 [[#FeedingTubeTypeCodelist]]
+
rect 578 417 702 467 [[#FeedingTubeTypeCodelist]]
rect 211 168 351 238 [[MedicationAdministration2-v1.0.1(2018EN)]]
+
rect 179 162 319 232 [[MedicationAdministration2-v1.0.1(2018EN)]]
rect 446 305 586 375 [[MedicalDevice-v3.1.1(2018EN)]]
+
rect 414 299 554 369 [[MedicalDevice-v3.2(2018EN)]]
rect 414 162 514 242 [[#12054]]
+
rect 382 156 482 236 [[#12054]]
 
desc none
 
desc none
 
</imagemap>
 
</imagemap>
Regel 148: Regel 148:
 
{|
 
{|
 
|-
 
|-
|[[Bestand: block.png | link=MedicalDevice-v3.1.1(2018EN)]]||[[MedicalDevice-v3.1.1(2018EN) |MedicalDevice]]
+
|[[Bestand: block.png | link=MedicalDevice-v3.2(2018EN)]]||[[MedicalDevice-v3.2(2018EN) |MedicalDevice]]
 
|}
 
|}
 
|-style="vertical-align:top; background-color: transparent; "
 
|-style="vertical-align:top; background-color: transparent; "
Regel 204: Regel 204:
 
{|
 
{|
 
|-
 
|-
|[[Bestand: block.png | link=MedicalDevice-v3.1.1(2018EN)]]||[[MedicalDevice-v3.1.1(2018EN) |MedicalDevice]]
+
|[[Bestand: block.png | link=MedicalDevice-v3.2(2018EN)]]||[[MedicalDevice-v3.2(2018EN) |MedicalDevice]]
 
|}
 
|}
 
|-style="vertical-align:top; background-color: transparent; "
 
|-style="vertical-align:top; background-color: transparent; "
Regel 264: Regel 264:
 
|Description<!--vsDescription-->
 
|Description<!--vsDescription-->
 
|-style="vertical-align:top; "
 
|-style="vertical-align:top; "
|<span title = "Jejunostomiesonde" >Jejunostomy tube</span>
+
|<span title = "Jejunostomiesonde">Jejunostomy tube</span>
 
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=126065006 126065006]
 
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=126065006 126065006]
 
|SNOMED CT
 
|SNOMED CT
Regel 270: Regel 270:
 
|Jejunostomie katheter
 
|Jejunostomie katheter
 
|-style="vertical-align:top; "
 
|-style="vertical-align:top; "
|<span title = "Gastrostomiekatheter" >Gastrostomy tube</span>
+
|<span title = "Gastrostomiekatheter">Gastrostomy tube</span>
 
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=470571004 470571004]
 
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=470571004 470571004]
 
|SNOMED CT
 
|SNOMED CT
Regel 276: Regel 276:
 
|Gastrostomie katheter
 
|Gastrostomie katheter
 
|-style="vertical-align:top; "
 
|-style="vertical-align:top; "
|<span title = "Status: deprecated" style = "color:red">Percutaneous endoscopic gastrostomy catheter</span>
+
|<span title = "Status: deprecated">Percutaneous endoscopic gastrostomy catheter [DEPRECATED]</span>
 
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=281414004 281414004]
 
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=281414004 281414004]
 
|SNOMED CT
 
|SNOMED CT
Regel 282: Regel 282:
 
|PEG sonde
 
|PEG sonde
 
|-style="vertical-align:top; "
 
|-style="vertical-align:top; "
|<span title = "Percutane radiologische gastrostomiekatheter" >Percutaneous radiological gastrostomy catheter</span>
+
|<span title = "Percutane radiologische gastrostomiekatheter">Percutaneous radiological gastrostomy catheter</span>
 
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=8921000146109 8921000146109]
 
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=8921000146109 8921000146109]
 
|SNOMED CT
 
|SNOMED CT
Regel 288: Regel 288:
 
|PRG sonde
 
|PRG sonde
 
|-style="vertical-align:top; "
 
|-style="vertical-align:top; "
|<span title = "Percutane endoscopische gastrojejunostomiekatheter" >Percutaneous endoscopic gastrojejunostomy catheter</span>
+
|<span title = "Percutane endoscopische gastrojejunostomiekatheter">Percutaneous endoscopic gastrojejunostomy catheter</span>
 
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=8851000146109 8851000146109]
 
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=8851000146109 8851000146109]
 
|SNOMED CT
 
|SNOMED CT
Regel 294: Regel 294:
 
|PEG-J sonde
 
|PEG-J sonde
 
|-style="vertical-align:top; "
 
|-style="vertical-align:top; "
|<span title = "Percutane endoscopische jejunostomiekatheter" >Percutaneous endoscopic jejunostomy catheter</span>
+
|<span title = "Percutane endoscopische jejunostomiekatheter">Percutaneous endoscopic jejunostomy catheter</span>
 
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=8911000146104 8911000146104]
 
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=8911000146104 8911000146104]
 
|SNOMED CT
 
|SNOMED CT
Regel 300: Regel 300:
 
|PEJ sonde
 
|PEJ sonde
 
|-style="vertical-align:top; "
 
|-style="vertical-align:top; "
|<span title = "Nasogastrische sonde" >Nasogastric tube</span>
+
|<span title = "Nasogastrische sonde">Nasogastric tube</span>
 
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=17102003 17102003]
 
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=17102003 17102003]
 
|SNOMED CT
 
|SNOMED CT
Regel 306: Regel 306:
 
|Neus-maagsonde
 
|Neus-maagsonde
 
|-style="vertical-align:top; "
 
|-style="vertical-align:top; "
|<span title = "Neus-jejunumsonde" >Nasojejunal tube</span>
+
|<span title = "Neus-jejunumsonde">Nasojejunal tube</span>
 
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=8581000146101 8581000146101]
 
|[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=8581000146101 8581000146101]
 
|SNOMED CT
 
|SNOMED CT
Regel 331: Regel 331:
 
==Information model references<!--ftReferences-->==
 
==Information model references<!--ftReferences-->==
 
====This information model refers to<!--ftRefersTo-->====
 
====This information model refers to<!--ftRefersTo-->====
*[[MedicalDevice-v3.1.1(2018EN)|MedicalDevice-v3.1.1]]
+
*[[MedicalDevice-v3.2(2018EN)|MedicalDevice-v3.2]]
 
*[[MedicationAdministration2-v1.0.1(2018EN)|MedicationAdministration2-v1.0.1]]
 
*[[MedicationAdministration2-v1.0.1(2018EN)|MedicationAdministration2-v1.0.1]]
====This inforation model is used in<!--ftReferredBy-->====
+
====This information model is used in<!--ftReferredBy-->====
 
:--
 
:--
 
==Technical specifications in HL7v3 CDA and HL7 FHIR<!--ftHeader-->==
 
==Technical specifications in HL7v3 CDA and HL7 FHIR<!--ftHeader-->==
Regel 339: Regel 339:
 
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro-->
 
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro-->
 
<ul>
 
<ul>
<li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2018bbr-?id=2.16.840.1.113883.2.4.3.11.60.8.4.2.10.3&effectiveDate=2018-10-01T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li>
+
<li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2018bbr-?id=2.16.840.1.113883.2.4.3.11.60.8.4.2.10.3&effectiveDate=2019-02-26T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li>
 
<li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2018}}</li>
 
<li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2018}}</li>
 
</ul>
 
</ul>
Regel 345: Regel 345:
 
This information model is also available as [[Media:nl.zorg.FeedingTubeSystem-v3.2(2018EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.zorg.FeedingTubeSystem-v3.2(2018EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]]<!--ftDownloads-->
 
This information model is also available as [[Media:nl.zorg.FeedingTubeSystem-v3.2(2018EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.zorg.FeedingTubeSystem-v3.2(2018EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]]<!--ftDownloads-->
 
==About this information<!--ftHeader2-->==
 
==About this information<!--ftHeader2-->==
The information in this wikipage is based on<!--ftInfoBase--> Prerelease 2018 #1 <BR>
+
The information in this wikipage is based on<!--ftInfoBase--> Prerelease 2018-2 <BR>
 
SNOMED CT and LOINC codes are based on:
 
SNOMED CT and LOINC codes are based on:
 
<ul>
 
<ul>
Regel 352: Regel 352:
 
</ul>
 
</ul>
 
Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR>
 
Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR>
This page is generated on 01/11/2018 22:23:47 with ZibExtraction v. 2.0.6879.31307<!--ftDate--> <BR>
+
This page is generated on 12/03/2019 17:18:15 with ZibExtraction v. 3.0.7010.25883<!--ftDate--> <BR>
 
-----
 
-----
 
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2018(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2018(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div>
 
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2018(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2018(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div>

Huidige versie van 13 mrt 2019 om 00:52


Attention!! This is not the most recent version of this information model. You can find the most recent version here.

General information

Name: nl.zorg.FeedingTubeSystem NL.png
Version: 3.2
HCIM Status:Final
Release: 2018
Release status: Prepublished
Release date: 26-02-2019


Back 16.png Back to HCIM list

Metadata

DCM::CoderList Werkgroep RadB Verpleegkundige Gegevens
DCM::ContactInformation.Address *
DCM::ContactInformation.Name *
DCM::ContactInformation.Telecom *
DCM::ContentAuthorList Werkgroep RadB Verpleegkundige Gegevens
DCM::CreationDate 3-4-2014
DCM::DeprecatedDate
DCM::DescriptionLanguage nl
DCM::EndorsingAuthority.Address
DCM::EndorsingAuthority.Name PM
DCM::EndorsingAuthority.Telecom
DCM::Id 2.16.840.1.113883.2.4.3.11.60.40.3.10.3
DCM::KeywordList Sonde, feeding tube, toedieningssyteem
DCM::LifecycleStatus Final
DCM::ModelerList Werkgroep RadB Verpleegkundige Gegevens
DCM::Name nl.zorg.SondeSysteem
DCM::PublicationDate 26-02-2019
DCM::PublicationStatus Prepublished
DCM::ReviewerList Projectgroep RadB Verpleegkundige Gegevens & Kerngroep Registratie aan de Bron
DCM::RevisionDate 31-12-2017
DCM::Superseeds nl.zorg.SondeSysteem-v3.1
DCM::Version 3.2
HCIM::PublicationLanguage EN

Revision History

Only available in Dutch

Publicatieversie 1.0 (01-07-2015)

Publicatieversie 3.0 (01-05-2016)

Publicatieversie 3.1 (04-09-2017)

ZIB-530 Verwijzingen naar de bouwsteen Verpleegkundige Interventie verwijderd
ZIB-545 Toevoegen sondelengte
ZIB-607 Aanpassen verwijzingen naar medicatie zib ivm nieuwe medicatie zib's

Publicatieversie 3.2 (31-12-2017)

ZIB-646 Aanpassing SNOMED codes

Concept

A feeding tube is a special catheter used to:

  • administer liquid food to people who are incapable of oral intake of food or liquid,
  • administer medication,
  • drain (siphon) or pump out gastric juice.


There are different ways to place a feeding tube. A feeding tube can be inserted through the nose, in the stomach or in the intestines (duodenum, jejunum).
Percutaneous endoscopic gastrostomy (PEG) is a technique in which a feeding tube is placed into the stomach through the abdominal wall. This thin tube (PEG tube) is used to feed a patient who is incapable of oral food intake for a prolonged period of time.

Purpose

The purpose of a feeding tube is usually to administer food and/or medication.
Information on present feeding tubes is recorded to inform other health professionals. This information is of importance in determining the care required for the patient and in safely administering medication. In a transfer situation, the information offers the option to realize continuity of care by organizing specific expertise and materials in advance, for example.

Information Model


#12057MedicalDevice-v3.2(2018EN)#12055#12051#FeedingTubeTypeCodelistMedicationAdministration2-v1.0.1(2018EN)MedicalDevice-v3.2(2018EN)#12054FeedingTubeSystem-v3.2Model(2018EN).png


Type Id Concept Card. Definition DefinitionCode Reference
Block.png NL-CM:10.3.1 Arrowdown.pngFeedingTubeSystem Root concept of the FeedingTubeSystem information model. This root concept contains all data elements of the FeedingTubeSystem information model.
Verwijzing.png NL-CM:10.3.2 Arrowright.pngFeedingTube::MedicalDevice 1 FeedingTube describes the presence of a feeding tube. If this is the case, the date of placement and insertion location can be described in addition to the type of feeding tube. Furthermore, it offers the option to record identification information of the feeding tube if desired.
83059008 Tube
Block.png MedicalDevice
CD.png NL-CM:10.1.3 Arrowright.pngProductType A description of the type of feeding tube based on the location where it was inserted and the position of the tip of the tube.
List2.png FeedingTubeTypeCodelist
PQ.png NL-CM:10.3.8 Arrowright.pngFeedingTubeLength 0..1 The input length of the feeding tube in cm for the patient in question as determined by formulas based on for example the NEX i.e. nosepoint-earlobe-xyphoid distance (adults) or body length (children).
Verwijzing.png NL-CM:10.3.3 Arrowright.pngEnteralNutrition::MedicationAdministration 0..* The description of the fluid administered through the feeding tube and the dose administered, as given in the medication prescription.

Though most cases involve food being administered through the feeding tube, medication is often administered through these tubes as well.

225748000 Artificial feed
Block.png MedicationAdministration2
Verwijzing.png NL-CM:10.3.7 Arrowright.pngMedicalDevice 0..1 A description of aids required to use the feeding tube, such as an enteral feeding pump or a vacuum pump in the event of draining fluid.
Block.png MedicalDevice
ST.png NL-CM:10.3.6 Arrowright.pngComment 0..1 A comment on the feeding tube.
48767-8 Annotation comment [Interpretation] Narrative

Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page List2.png

Example Instances

Only available in Dutch

SondeSysteem
Sonde
ProductType PEG sonde
SondeLengte --
BeginDatum 30-11-2014
SondeVoeding
ProductNaam Nutrison

References

1. V&VN. Landelijke multidisciplinaire richtlijn Neusmaagsonde. (2011) [Online] Beschikbaar op:http://www.stuurgroepondervoeding.nl/wp-content/uploads/2015/02/Richtlijn-Neusmaagsonde-definitief.pdf [Geraadpleegd: 13 februari 2015]

Valuesets

FeedingTubeTypeCodelist

Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.10.3.1 Binding: Extensible
Conceptname Conceptcode Codesystem name Codesystem OID Description
Jejunostomy tube 126065006 SNOMED CT 2.16.840.1.113883.6.96 Jejunostomie katheter
Gastrostomy tube 470571004 SNOMED CT 2.16.840.1.113883.6.96 Gastrostomie katheter
Percutaneous endoscopic gastrostomy catheter [DEPRECATED] 281414004 SNOMED CT 2.16.840.1.113883.6.96 PEG sonde
Percutaneous radiological gastrostomy catheter 8921000146109 SNOMED CT 2.16.840.1.113883.6.96 PRG sonde
Percutaneous endoscopic gastrojejunostomy catheter 8851000146109 SNOMED CT 2.16.840.1.113883.6.96 PEG-J sonde
Percutaneous endoscopic jejunostomy catheter 8911000146104 SNOMED CT 2.16.840.1.113883.6.96 PEJ sonde
Nasogastric tube 17102003 SNOMED CT 2.16.840.1.113883.6.96 Neus-maagsonde
Nasojejunal tube 8581000146101 SNOMED CT 2.16.840.1.113883.6.96 Neus-jejunumsonde
Nasoduodenal tube 8591000146104 SNOMED CT 2.16.840.1.113883.6.96 Neus-duodenumsonde
Other OTH NullFlavor 2.16.840.1.113883.5.1008 Anders

This information model in other releases

Information model references

This information model refers to

This information model is used in

--

Technical specifications in HL7v3 CDA and HL7 FHIR

To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:

  • HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment Artdecor.jpg
  • HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR Fhir.png

Downloads

This information model is also available as pdf file PDF.png or as spreadsheet Xlsx.png

About this information

The information in this wikipage is based on Prerelease 2018-2
SNOMED CT and LOINC codes are based on:

  • SNOMED Clinical Terms version: 20180731 [R] (July 2018 Release)
  • LOINC version 2.64

Conditions for use are located on the mainpage List2.png
This page is generated on 12/03/2019 17:18:15 with ZibExtraction v. 3.0.7010.25883


Back 16.png Back to HCIM list