Refraction-v1.0(2020EN)

Uit Zorginformatiebouwstenen
Ga naar: navigatie, zoeken


Attention!! This is not the most recent version of this information model. You can find the most recent version ''here''.

General information

Name: nl.zorg.Refraction NL.png
Version: 1.0
HCIM Status:Final
Release: 2020
Release status: Published
Release date: 01-09-2020


Back 16.png Back to HCIM list

Metadata

DCM::CoderList *
DCM::ContactInformation.Address *
DCM::ContactInformation.Name *
DCM::ContactInformation.Telecom *
DCM::ContentAuthorList *
DCM::CreationDate 17-5-2020
DCM::DeprecatedDate
DCM::DescriptionLanguage nl
DCM::EndorsingAuthority.Address
DCM::EndorsingAuthority.Name *
DCM::EndorsingAuthority.Telecom
DCM::Id 2.16.840.1.113883.2.4.3.11.60.40.3.12.20
DCM::KeywordList
DCM::LifecycleStatus Final
DCM::ModelerList *
DCM::Name nl.zorg.Refractie
DCM::PublicationDate 01-09-2020
DCM::PublicationStatus Published
DCM::ReviewerList
DCM::RevisionDate
DCM::Supersedes *
DCM::Version 1.0
HCIM::PublicationLanguage EN

Revision History

Only available in Dutch

Publicatieversie 1.0 (01-09-2020).

Concept

The refraction measurement is a measurement with which the refractive error of the eye is determined. During the refraction measurement, the necessary correction is established: the spherical power (in diopter), the cylindrical power (in diopter), the axis direction(in degrees) for any cylindrical correction, the prism (in diopter)and any additional power of the reading area (in diopter), the so-called reading addition

Purpose

The purpose of a refraction measurement is to determine the correction (through glasses or lenses) with which the patient can see optimally.

Patient Population

Adults and children from the age that they can interpret a picture chart.

Information Model


#LateralityCodelist#14344#14351#RefractionMeasurementMethodCodelist#14354#14348#14339#14338#14349#14346#14340#14353#14355#14341#14352AnatomicalLocation-v1.0(2020EN)#14347Refraction-v1.0Model(2020EN).png


Type Id Concept Card. Definition DefinitionCode Reference
Block.png NL-CM:12.20.1 Arrowdown.pngRefraction Root concept of the Refractie information model.This root concept contains all data elements of the Refraction information model.
251718005 Refractive power
CD.png NL-CM:12.20.4 Arrowright.pngRefractionMeasurementMethod 0..1 The method used to measure the refraction.
251794006 Refraction
List2.png RefractionMeasurementMethodCodelist
TS.png NL-CM:12.20.3 Arrowright.pngRefractionDateTime 0..1 The date and time when the refraction measurement was carried out.
439771001 Date of event
Folder.png NL-CM:12.20.12 Arrowdown.pngCilindricalRefraction 0..1 Container of the CilindricalRefraction concept.This container contains all data elements of the CilindricalRefraction concept.
PQ.png NL-CM:12.20.11 Arrowright.pngCylindricalRefractionValue 1 The power of the cylinder needed to correct the cylindrical error (astigmatism), expressed in diopters. When a cylindrical refraction is registered, the axis of the cylinder must also be specified.
251797004 Power of cylinder
PQ.png NL-CM:12.20.13 Arrowright.pngCilindricRefractionAxis 1 The axis direction of the cylindrical refraction value expressed in degrees.
251799001 Axis of cylinder
Folder.png NL-CM:12.20.5 Arrowdown.pngPrisma 0..1 Container of the Prisma concept.This container contains all data elements of the Prisma container.
PQ.png NL-CM:12.20.6 Arrowright.pngPrismaValue 1 The power of the prism, expressed in diopters.
251762001 Prism strength
PQ.png NL-CM:12.20.7 Arrowright.pngPrismaBase 1 The base of the prism, expressed in degrees.
246223004 Prism base direction
Folder.png NL-CM:12.20.14 Arrowdown.pngSfericRefraction 0..1 Container of the SfericRefraction concept.This container contains all data elements of the SfericRefraction concept.
PQ.png NL-CM:12.20.9 Arrowright.pngSfericRefractionValue 1 The spherical spectacle strength power needed to correct nearsightedness (myopia) or farsightedness (hyperopia), expressed in diopters, ascending by 0.25D.
251795007 Power of sphere
PQ.png NL-CM:12.20.10 Arrowright.pngSfericalEquivalent 0..1 The spherical power added to half of the cylindrical power. Expressed in diopters, ascending by 0.1D. Some equipment automatically calculates the spherical equivalent automatically.
PQ.png NL-CM:12.20.8 Arrowright.pngReadAddition 0..1 A supplement that is added to the refraction value to determine the strength of the reading glasses, expressed in diopters.
251718005 Refractive power
Verwijzing.png NL-CM:12.20.2 Arrowright.pngAnatomicalLocation 0..1 The laterality of the eye whose of which the refraction has been measured.
272741003 Laterality
Block.png AnatomicalLocation
CD.png NL-CM:12.20.15 Arrowright.pngLaterality Laterality adds information about body site to the anatomic location, e.g. left. 
List2.png LateralityCodelist

Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page List2.png

Example Instances

Only available in Dutch

Refractie DatumTijd Refractie Methode Refractie Lateraliteit Prisma Cilindrische Refractie Sferisch Equivalent Lees
Additie
Waarde Basis Waarde As Equivalent Waarde
01-01-2020 Objectieve refractie Rechts 2.00 90 -0.75 900 +0.63 +1.00 +2.00
01-01-2020 Objectieve refractie Links 1.50 45 -1.00 00 0 +0.5 +2.00
12-01-2020
Subjectieve refractie Rechts -- -- -- -- -- +1.50 --
12-01-2020
Subjectieve refractie Links -- -- -- -- -- +2.00 --

Valuesets

LateralityCodelist

Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.12.20.2 Binding: Required
Conceptname Conceptcode Codesystem name Codesystem OID Description
Left 7771000 SNOMED CT 2.16.840.1.113883.6.96 Links
Right 24028007 SNOMED CT 2.16.840.1.113883.6.96 Rechts

RefractionMeasurementMethodCodelist

Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.12.20.1 Binding: Extensible
Conceptname Conceptcode Codesystem name Codesystem OID Description
Subjective refraction 397277005 SNOMED CT 2.16.840.1.113883.6.96 Subjectieve refractie
Objective refraction 397276001 SNOMED CT 2.16.840.1.113883.6.96 Objectieve refractie

This information model in other releases

Information model references

This information model refers to

This information model is used in

--

Technical specifications in HL7v3 CDA and HL7 FHIR

To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:

  • HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment Artdecor.jpg
  • HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR Fhir.png

Downloads

This information model is also available as pdf file PDF.png or as spreadsheet Xlsx.png

About this information

The information in this wikipage is based on Release 2020
SNOMED CT and LOINC codes are based on:

  • SNOMED Clinical Terms version: 20200309 [R] (March 2020 Interim Release)
  • LOINC version 2.67

Conditions for use are located on the mainpage List2.png
This page is generated on 19/09/2020 21:02:19 with ZibExtraction v. 4.0.7556.18438


Back 16.png Back to HCIM list