Refraction-v1.0(2020EN): verschil tussen versies

Uit Zorginformatiebouwstenen
Ga naar: navigatie, zoeken
(Technical specifications in HL7v3 CDA and HL7 FHIR)
 
(Een tussenliggende versie door een andere gebruiker niet weergegeven)
Regel 113: Regel 113:
 
{|
 
{|
 
|-
 
|-
|<span title = "Codesystem: SNOMED CT (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251718005 251718005] Refractive power</span>
+
|<span title = "Codesystem: SNOMED CT; Refractiesterkte (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251718005 251718005] Refractive power</span>
 
|}
 
|}
 
|
 
|
Regel 166: Regel 166:
 
{|
 
{|
 
|-
 
|-
|<span title = "Codesystem: SNOMED CT (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251797004 251797004] Power of cylinder</span>
+
|<span title = "Codesystem: SNOMED CT; Cillindersterkte (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251797004 251797004] Power of cylinder</span>
 
|}
 
|}
 
|
 
|
Regel 180: Regel 180:
 
{|
 
{|
 
|-
 
|-
|<span title = "Codesystem: SNOMED CT (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251799001 251799001] Axis of cylinder</span>
+
|<span title = "Codesystem: SNOMED CT; As van cilinder (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251799001 251799001] Axis of cylinder</span>
 
|}
 
|}
 
|
 
|
Regel 204: Regel 204:
 
{|
 
{|
 
|-
 
|-
|<span title = "Codesystem: SNOMED CT (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251762001 251762001] Prism strength</span>
+
|<span title = "Codesystem: SNOMED CT; Prismasterkte (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251762001 251762001] Prism strength</span>
 
|}
 
|}
 
|
 
|
Regel 219: Regel 219:
 
{|
 
{|
 
|-
 
|-
|<span title = "Codesystem: SNOMED CT (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=246223004 246223004] Prism base direction</span>
+
|<span title = "Codesystem: SNOMED CT; Richting van basis van prisma (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=246223004 246223004] Prism base direction</span>
 
|}
 
|}
 
|
 
|
Regel 242: Regel 242:
 
{|
 
{|
 
|-
 
|-
|<span title = "Codesystem: SNOMED CT (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251795007 251795007] Power of sphere</span>
+
|<span title = "Codesystem: SNOMED CT; Sferische sterkte (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251795007 251795007] Power of sphere</span>
 
|}
 
|}
 
|
 
|
Regel 265: Regel 265:
 
{|
 
{|
 
|-
 
|-
|<span title = "Codesystem: SNOMED CT (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251718005 251718005] Refractive power</span>
+
|<span title = "Codesystem: SNOMED CT; Refractiesterkte (observable entity)" >[https://terminologie.nictiz.nl/art-decor/snomed-ct?conceptId=251718005 251718005] Refractive power</span>
 
|}
 
|}
 
|
 
|
Regel 438: Regel 438:
 
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro-->
 
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:<!--ftReferenceIntro-->
 
<ul>
 
<ul>
<li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2020bbr-?id=2.16.840.1.113883.2.4.3.11.60.10.4.2.12.20&effectiveDate=2020-09-01T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li>
+
<li>HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment<!--ftArtDecorReference--> [http://decor.nictiz.nl/art-decor/decor-scenarios--zib2020bbr-?id=2.16.840.1.113883.2.4.3.11.60.121.4.2.12.20&effectiveDate=2020-09-01T00:00:00&language=en-US&scenariotree=false [[File:artdecor.jpg|16px|link=]]]</li>
<li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2020}}</li>
+
<li>HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR<!--ftSimplifierReference--> {{SimplefierLinks|2020|Refraction}}</li>
 
</ul>
 
</ul>
 +
 
==Downloads<!--ftDownloadTitle-->==
 
==Downloads<!--ftDownloadTitle-->==
 
This information model is also available as [[Media:nl.zorg.Refraction-v1.0(2020EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.zorg.Refraction-v1.0(2020EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]]<!--ftDownloads-->
 
This information model is also available as [[Media:nl.zorg.Refraction-v1.0(2020EN).pdf|pdf file]] [[File:PDF.png|link=]] or as [[Media:nl.zorg.Refraction-v1.0(2020EN).xlsx|spreadsheet]] [[File:xlsx.png|link=]]<!--ftDownloads-->
Regel 447: Regel 448:
 
SNOMED CT and LOINC codes are based on:
 
SNOMED CT and LOINC codes are based on:
 
<ul>
 
<ul>
<li>SNOMED Clinical Terms version: 20200309 [R] (March 2020 Interim Release)</li>
+
<li>SNOMED Clinical Terms version: 20200731 [R] (July 2020 Release)</li>
 
<li>LOINC version 2.67</li>
 
<li>LOINC version 2.67</li>
 
</ul>
 
</ul>
 
Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR>
 
Conditions for use are located on the mainpage<!--ftConditions--> [[Bestand:list2.png|link=HCIM_Mainpage<!--wikiMainpage-->]]<BR>
This page is generated on 19/09/2020 21:02:19 with ZibExtraction v. 4.0.7556.18438<!--ftDate--> <BR>
+
This page is generated on 29/09/2020 21:24:19 with ZibExtraction v. 4.0.7577.31095<!--ftDate--> <BR>
 
-----
 
-----
 
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2020(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2020(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div>
 
<div style="text-align: right; direction: ltr; margin-left: 1em;" >[[Bestand: Back 16.png| link= HCIM_Release<!--wikiReleasePage-->_2020(EN)]] [[HCIM_Release<!--wikiReleasePage-->_2020(EN) |Back to HCIM list<!--hdBackToMainPage--> ]]</div>

Huidige versie van 8 dec 2023 om 11:54


Attention!! This is not the most recent version of this information model. You can find the most recent version ''here''.

General information

Name: nl.zorg.Refraction NL.png
Version: 1.0
HCIM Status:Final
Release: 2020
Release status: Published
Release date: 01-09-2020


Back 16.png Back to HCIM list

Metadata

DCM::CoderList *
DCM::ContactInformation.Address *
DCM::ContactInformation.Name *
DCM::ContactInformation.Telecom *
DCM::ContentAuthorList *
DCM::CreationDate 17-5-2020
DCM::DeprecatedDate
DCM::DescriptionLanguage nl
DCM::EndorsingAuthority.Address
DCM::EndorsingAuthority.Name *
DCM::EndorsingAuthority.Telecom
DCM::Id 2.16.840.1.113883.2.4.3.11.60.40.3.12.20
DCM::KeywordList
DCM::LifecycleStatus Final
DCM::ModelerList *
DCM::Name nl.zorg.Refractie
DCM::PublicationDate 01-09-2020
DCM::PublicationStatus Published
DCM::ReviewerList
DCM::RevisionDate
DCM::Supersedes *
DCM::Version 1.0
HCIM::PublicationLanguage EN

Revision History

Only available in Dutch

Publicatieversie 1.0 (01-09-2020).

Concept

The refraction measurement is a measurement with which the refractive error of the eye is determined. During the refraction measurement, the necessary correction is established: the spherical power (in diopter), the cylindrical power (in diopter), the axis direction(in degrees) for any cylindrical correction, the prism (in diopter)and any additional power of the reading area (in diopter), the so-called reading addition

Purpose

The purpose of a refraction measurement is to determine the correction (through glasses or lenses) with which the patient can see optimally.

Patient Population

Adults and children from the age that they can interpret a picture chart.

Information Model


#LateralityCodelist#14344#14351#RefractionMeasurementMethodCodelist#14354#14348#14339#14338#14349#14346#14340#14353#14355#14341#14352AnatomicalLocation-v1.0(2020EN)#14347Refraction-v1.0Model(2020EN).png


Type Id Concept Card. Definition DefinitionCode Reference
Block.png NL-CM:12.20.1 Arrowdown.pngRefraction Root concept of the Refractie information model.This root concept contains all data elements of the Refraction information model.
251718005 Refractive power
CD.png NL-CM:12.20.4 Arrowright.pngRefractionMeasurementMethod 0..1 The method used to measure the refraction.
251794006 Refraction
List2.png RefractionMeasurementMethodCodelist
TS.png NL-CM:12.20.3 Arrowright.pngRefractionDateTime 0..1 The date and time when the refraction measurement was carried out.
439771001 Date of event
Folder.png NL-CM:12.20.12 Arrowdown.pngCilindricalRefraction 0..1 Container of the CilindricalRefraction concept.This container contains all data elements of the CilindricalRefraction concept.
PQ.png NL-CM:12.20.11 Arrowright.pngCylindricalRefractionValue 1 The power of the cylinder needed to correct the cylindrical error (astigmatism), expressed in diopters. When a cylindrical refraction is registered, the axis of the cylinder must also be specified.
251797004 Power of cylinder
PQ.png NL-CM:12.20.13 Arrowright.pngCilindricRefractionAxis 1 The axis direction of the cylindrical refraction value expressed in degrees.
251799001 Axis of cylinder
Folder.png NL-CM:12.20.5 Arrowdown.pngPrisma 0..1 Container of the Prisma concept.This container contains all data elements of the Prisma container.
PQ.png NL-CM:12.20.6 Arrowright.pngPrismaValue 1 The power of the prism, expressed in diopters.
251762001 Prism strength
PQ.png NL-CM:12.20.7 Arrowright.pngPrismaBase 1 The base of the prism, expressed in degrees.
246223004 Prism base direction
Folder.png NL-CM:12.20.14 Arrowdown.pngSfericRefraction 0..1 Container of the SfericRefraction concept.This container contains all data elements of the SfericRefraction concept.
PQ.png NL-CM:12.20.9 Arrowright.pngSfericRefractionValue 1 The spherical spectacle strength power needed to correct nearsightedness (myopia) or farsightedness (hyperopia), expressed in diopters, ascending by 0.25D.
251795007 Power of sphere
PQ.png NL-CM:12.20.10 Arrowright.pngSfericalEquivalent 0..1 The spherical power added to half of the cylindrical power. Expressed in diopters, ascending by 0.1D. Some equipment automatically calculates the spherical equivalent automatically.
PQ.png NL-CM:12.20.8 Arrowright.pngReadAddition 0..1 A supplement that is added to the refraction value to determine the strength of the reading glasses, expressed in diopters.
251718005 Refractive power
Verwijzing.png NL-CM:12.20.2 Arrowright.pngAnatomicalLocation 0..1 The laterality of the eye whose of which the refraction has been measured.
272741003 Laterality
Block.png AnatomicalLocation
CD.png NL-CM:12.20.15 Arrowright.pngLaterality Laterality adds information about body site to the anatomic location, e.g. left. 
List2.png LateralityCodelist

Columns Concept and DefinitionCode: hover over the values for more information
For explanation of the symbols, please see the legend page List2.png

Example Instances

Only available in Dutch

Refractie DatumTijd Refractie Methode Refractie Lateraliteit Prisma Cilindrische Refractie Sferisch Equivalent Lees
Additie
Waarde Basis Waarde As Equivalent Waarde
01-01-2020 Objectieve refractie Rechts 2.00 90 -0.75 900 +0.63 +1.00 +2.00
01-01-2020 Objectieve refractie Links 1.50 45 -1.00 00 0 +0.5 +2.00
12-01-2020
Subjectieve refractie Rechts -- -- -- -- -- +1.50 --
12-01-2020
Subjectieve refractie Links -- -- -- -- -- +2.00 --

Valuesets

LateralityCodelist

Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.12.20.2 Binding: Required
Conceptname Conceptcode Codesystem name Codesystem OID Description
Left 7771000 SNOMED CT 2.16.840.1.113883.6.96 Links
Right 24028007 SNOMED CT 2.16.840.1.113883.6.96 Rechts

RefractionMeasurementMethodCodelist

Valueset OID: 2.16.840.1.113883.2.4.3.11.60.40.2.12.20.1 Binding: Extensible
Conceptname Conceptcode Codesystem name Codesystem OID Description
Subjective refraction 397277005 SNOMED CT 2.16.840.1.113883.6.96 Subjectieve refractie
Objective refraction 397276001 SNOMED CT 2.16.840.1.113883.6.96 Objectieve refractie

This information model in other releases

Information model references

This information model refers to

This information model is used in

--

Technical specifications in HL7v3 CDA and HL7 FHIR

To exchange information based on health and care information models, additional, more technical specifications are required.
Not every environment can handle the same technical specifications. For this reason, there are several types of technical specifications:

  • HL7® version 3 CDA compatible specifications, available through the Nictiz ART-DECOR® environment Artdecor.jpg
  • HL7® FHIR® compatible specifications, available through the Nictiz environment on the Simplifier FHIR Fhir.png

Downloads

This information model is also available as pdf file PDF.png or as spreadsheet Xlsx.png

About this information

The information in this wikipage is based on Release 2020
SNOMED CT and LOINC codes are based on:

  • SNOMED Clinical Terms version: 20200731 [R] (July 2020 Release)
  • LOINC version 2.67

Conditions for use are located on the mainpage List2.png
This page is generated on 29/09/2020 21:24:19 with ZibExtraction v. 4.0.7577.31095


Back 16.png Back to HCIM list